top of page

Home  ›  Products  ›  Shear Fixtures  ›  V-Notched Rail Shear Fixture

UGC-SF-250 V-notched rail shear grips for ASTM D7078 composite shear testing by Universal Grip
UGC-SF-250 V-notched rail shear grips for ASTM D7078 composite shear testing by Universal Grip
UGC-SF-250 V-Notched Rail Shear Fixture by Universal Grip, view 2
UGC-SF-250 V-Notched Rail Shear Fixture by Universal Grip, view 3
UGC-SF-250 V-Notched Rail Shear Fixture by Universal Grip, view 4

V-Notched Rail Shear Fixture – ASTM D7078, 50 kN / 100 kN

Pair of V-notched rail shear grips for composites to ASTM D7078, in 50 kN and 100 kN versions plus a -100 to +600 °C high-temperature version.

Brand: Universal Grip  |  Model: UGC-SF-250  |  ● Configured to order

  • Built for the ASTM D7078 V-notched rail shear method

  • 50 kN and 100 kN versions (11,240 / 22,480 lbf), clamping to 75 / 150 kN

  • Hardened 58 HRC jaws with 1.2 x 45° pyramid serrations

  • Bolted clamping at 55 Nm (50 kN) or 120 Nm (100 kN) for repeatable grip

  • Nylon positioning tools included for consistent specimen alignment

  • High-temperature 20 kN version, TiAlN-coated, rated -100 to +600 °C

Standards: ASTM D7078

Trusted by Global Companies

V-notched rail shear grips for composite laminates

The UGC-SF-250 is a pair of V-notched rail shear grips for measuring the shear properties of composite materials to ASTM D7078. It is aimed at composite test labs and aerospace materials groups that want a large, uniform shear zone and tension-mode loading on a standard universal testing machine.

 

How it works

The V-notched specimen is bolted between serrated jaws on two rails, and each grip connects to the machine through a clevis. As the crosshead pulls the grips apart, the rails move parallel to each other and load the notched section of the specimen in shear. The result is a larger shear zone than a notched beam offers.

Clamping is done with bolts tightened to a defined torque: 55 Nm (40.6 lbf·ft) on the 50 kN grips and 120 Nm (88.5 lbf·ft) on the 100 kN grips, so every specimen sees the same clamping force. The hardened 58 HRC jaws have pyramid serrations of 1.2 x 45° to hold the laminate without slip, and the supplied nylon positioning tools set each specimen in the same place between the rails.

See our complete ASTM D7078 guide for specimen geometry, procedure and calculations.

 

Versions

  • 50 kN: 50 kN test load, 75 kN clamping capacity; female clevis Ø 31.8 mm (1-1/4 in); supplied as one pair.

  • 100 kN: 100 kN test load, 150 kN clamping capacity; female clevis Ø 31.8 mm or Ø 40 mm (1.57 in); one pair.

  • High-temperature special, 20 kN (4,496 lbf): hardened and TiAlN-coated for -100 to +600 °C (-148 to 1,112 °F), with an M16 female thread connection.

The standard grips are nickel-plated steel, weigh 4 kg (8.8 lb) each and are rated for 0 to +70 °C; other ranges are available on request.

 

Machine fit

The 50 kN pair matches a 50 kN benchtop UTM; the 100 kN pair a 100 kN benchtop UTM or a Galdabini floor-standing frame. The high-temperature version is intended for use inside an environmental chamber. Other couplings are available on request, or through our adapters.

For smaller coupons loaded through a compression probe, compare the UGC-SF-230 V-notched beam fixture for ASTM D5379.

Tell us the capacity, your machine coupling and test temperature range, and we will quote the right pair.

Product video

At a glance

  • Test type: V-notched rail shear, tension mode

  • Max. load: 50 kN or 100 kN (11,240 / 22,480 lbf)

  • Clamping capacity: 75 kN (50 kN version) / 150 kN (100 kN version)

  • Clamping torque: 55 Nm (50 kN) / 120 Nm (100 kN)

  • Jaws: Hardened steel 58 HRC, pyramid serrated 1.2 x 45°

  • Coupling: Female clevis Ø 31.8 mm (1-1/4 in); 100 kN also Ø 40 mm; others on request

V-Notched Rail Shear Fixture Specifications

TEST TYPE

V-notched rail shear, tension mode

 

MAX. LOAD

50 kN or 100 kN (11,240 / 22,480 lbf)

 

CLAMPING CAPACITY

75 kN (50 kN version) / 150 kN (100 kN version)

 

CLAMPING TORQUE

55 Nm (50 kN) / 120 Nm (100 kN)

 

JAWS

Hardened steel 58 HRC, pyramid serrated 1.2 x 45°

 

COUPLING

Female clevis Ø 31.8 mm (1-1/4 in); 100 kN also Ø 40 mm; others on request

 

MATERIAL

Steel, nickel-plated

 

TEMPERATURE RANGE

0 … +70 °C (others on request)

 

HIGH-TEMPERATURE VERSION

20 kN, TiAlN-coated, -100 … +600 °C, M16 female thread

 

WEIGHT

4 kg (8.8 lb) per grip

 

SUPPLIED AS

1 pair, with nylon positioning tools

 

PART REF.

UGC-SF-250

 

Models & Options

  • 50 kN version — Female clevis Ø 31.8 mm (1-1/4 in), 1 pair, 55 Nm clamping torque (Specify at order)

  • 100 kN version — Female clevis Ø 31.8 mm or Ø 40 mm, 1 pair, 120 Nm clamping torque (Specify at order)

  • High-temperature special, 20 kN — Hardened, TiAlN-coated; -100 … +600 °C; M16 female thread (Specify at order)

  • Other couplings — Clevis or thread sizes to suit your machine (On request)

What's Included

  • One pair of V-notched rail shear grips with serrated jaws and clamping bolts

  • Nylon positioning tools for specimen alignment

  • Clevis coupling per version (Ø 31.8 mm, or Ø 40 mm on the 100 kN pair)

Supported Test Standards

  • ASTM D7078 — Shear properties of composite materials by the V-notched rail shear method

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-230 V-Notched Beam Shear Fixture

UGC-SF-230 V-Notched Beam Shear Fixture

Iosipescu V-notched beam shear fixture for composite laminates, rated to 50 kN, with the compression probe and specimen

UGC-SF-240 Plastics Shear Punch Fixture

UGC-SF-240 Plastics Shear Punch Fixture

Punch-tool shear fixture for plastic sheet to ASTM D732 that cuts a 25.4 mm disk, offered as a 20 kN clevis version or a

UGC-SF-260 Kramer Shear Cell for Food

UGC-SF-260 Kramer Shear Cell for Food

Ten-blade Kramer shear-compression cell for measuring the firmness of fruit, vegetables, meat and processed foods, rated

UGC-SF-270 O-Ring Composite Shear Fixture

UGC-SF-270 O-Ring Composite Shear Fixture

Special shear fixture for ring-shaped composite samples 70 to 170 mm in diameter, with stepped seats on two steel blocks

V-Notched Rail Shear Fixture FAQ

Which test method are these grips for?

The ASTM D7078 V-notched rail shear test for composites. Our ASTM D7078 guide covers specimens, procedure and calculations.

 

What torque should the clamping bolts be tightened to?

55 Nm on the 50 kN grips and 120 Nm on the 100 kN grips.

 

What is the difference between the 50 kN and 100 kN versions?

Test load, clamping capacity (75 kN vs 150 kN) and coupling: the 100 kN pair is available with a Ø 31.8 mm or Ø 40 mm clevis.

 

Can I test at high or low temperature?

Yes, with the high-temperature special version. It is hardened and TiAlN-coated for -100 to +600 °C, rated to 20 kN, with an M16 female thread. Pair it with an environmental chamber.

 

What are the nylon positioning tools for?

They locate the specimen in the same position between the rails each time, which keeps alignment consistent across a test series.

 

Are the grips supplied as a pair?

Yes. Each version is supplied as one pair; each standard grip weighs 4 kg.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page