top of page

Home  ›  Products  ›  Shear Fixtures  ›  Dispersion Adhesive Shear Fixture EN 1324

UGC-SF-210 dispersion adhesive shear fixture for EN 1324 and ISO 13007-2 by Universal Grip
UGC-SF-210 dispersion adhesive shear fixture for EN 1324 and ISO 13007-2 by Universal Grip
UGC-SF-210 Dispersion Adhesive Shear Fixture EN 1324 by Universal Grip, view 2
UGC-SF-210 Dispersion Adhesive Shear Fixture EN 1324 by Universal Grip, view 3
Product photo 4

Dispersion Adhesive Shear Fixture EN 1324

Shear adhesion fixture for dispersion and tile adhesives, rated to 20 kN, for EN 1324 Fig. 3, EN 12003 Fig. 3 and ISO 13007-2 Fig. 10 tests.

Brand: Universal Grip  |  Model: UGC-SF-210  |  ● Configured to order

  • Set up for EN 1324 Fig. 3, EN 12003 Fig. 3, ISO 13007-2 Fig. 10 and EN 12004-2 Fig. 4

  • Loads the adhesive layer parallel to the bond, in pure shear

  • Rated to 20 kN (4,496 lbf) maximum test load

  • Nickel-coated steel resists corrosion from cementitious and water-based products

  • Ø 15.9 mm (5/8 in) female clevis; other couplings on request

  • Approx. 2.8 kg, specified for 0 to +70 °C

Standards: EN 1324  ·  EN 12003  ·  ISO 13007-2  ·  EN 12004-2

Trusted by Global Companies

Shear adhesion testing of dispersion and tile adhesives

The UGC-SF-210 is for building chemicals manufacturers and construction products labs that classify tile adhesives by their shear adhesion strength. It holds a bonded tile assembly and loads it parallel to the adhesive layer until the bond fails in shear, following the arrangement shown in EN 1324 Fig. 3, EN 12003 Fig. 3, ISO 13007-2 Fig. 10 and EN 12004-2 Fig. 4. One fixture therefore covers the dispersion adhesive and reaction resin adhesive methods used in European and ISO product classification.

 

How it works

The bonded specimen is placed in the fixture so that one tile is restrained and the other is pushed along the bond plane. Because the load acts parallel to the adhesive layer, the result is a shear adhesion strength rather than a tensile pull-off value, and it can be compared directly across conditioning regimes such as dry, water immersion or heat aging specified by the standard you follow.

The body is nickel-coated steel, which stands up to the alkaline residue and moisture that tile adhesive specimens bring onto the test bench. The fixture weighs approx. 2.8 kg and is specified for 0 to +70 °C (32 to 158 °F).

 

Machine fit

The fixture is rated to 20 kN (4,496 lbf) and connects with a female clevis with a Ø 15.9 mm (5/8 in) pin. A 25 kN benchtop universal testing machine covers the full rating with margin; a 10 kN frame is enough where your adhesive classes fail well below that. Other couplings and adapters are available.

 

Which tile adhesive fixture?

The same standards contain more than one test figure. This fixture covers EN 1324 Fig. 3 and ISO 13007-2 Fig. 10. For the compression-mode arrangement of EN 1324 Fig. 2 and ISO 13007-2 Fig. 9, and for ANSI A118.1 testing in the US, use UGC-SF-220, the tile adhesive shear fixture. If you are not sure which figure your specification calls for, send us the standard and clause and we will confirm.

 

Typical applications

  • Dispersion (ready-mixed) tile adhesives

  • Ceramic tile adhesives

  • Building chemicals development and QC

  • Third-party construction products labs

For block-shear tests on rigid adhesive joints, see UGC-SF-170, the adhesive shear strength fixture, and our adhesives testing page. Tell us the standard and figure, your tile specimen size and machine coupling, and we will quote the fixture.

Product video

At a glance

  • Test type: Shear adhesion strength

  • Max. load: 20 kN (4,496 lbf)

  • Loading: Parallel to the adhesive layer

  • Coupling: Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

  • Material: Steel, nickel coating

  • Temperature range: 0 … +70 °C

Dispersion Adhesive Shear Fixture EN 1324 Specifications

TEST TYPE

Shear adhesion strength

 

MAX. LOAD

20 kN (4,496 lbf)

 

LOADING

Parallel to the adhesive layer

 

COUPLING

Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

 

MATERIAL

Steel, nickel coating

 

TEMPERATURE RANGE

0 … +70 °C

 

WEIGHT

Approx. 2.8 kg

 

SCOPE OF DELIVERY

1 fixture

 

STANDARDS

EN 1324 Fig. 3, EN 12003 Fig. 3, ISO 13007-2 Fig. 10, EN 12004-2 Fig. 4

 

DRAWINGS

Dimensional drawings on data sheet; 3D models on request

 

PART REF.

UGC-SF-210

 

Models & Options

  • Shear adhesion fixture — State the standard and figure plus tile specimen size (Specify at order)

  • Other couplings — Alternatives to the Ø 15.9 mm female clevis (On request)

What's Included

  • 1 shear adhesion fixture, nickel-coated steel

  • Ø 15.9 mm (5/8 in) female clevis coupling

  • Adapters for other machine couplings available on request

Supported Test Standards

  • EN 1324 — Adhesives for tiles – shear adhesion strength of dispersion adhesives

  • EN 12003 — Adhesives for tiles – shear adhesion strength of reaction resin adhesives

  • ISO 13007-2 — Ceramic tiles – grouts and adhesives – test methods for adhesives

  • EN 12004-2 — Adhesives for ceramic tiles – test methods

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-170 Adhesive Shear Strength Fixture ISO 13445

UGC-SF-170 Adhesive Shear Strength Fixture ISO 13445

Block-shear fixture for adhesive bonds between rigid substrates, rated to 20 kN, with interchangeable inserts for ASTM D

UGC-SF-220 Tile Adhesive Shear Fixture EN 12003

UGC-SF-220 Tile Adhesive Shear Fixture EN 12003

Compression shear fixture for tile adhesives and mortars with a 12–45 mm jaw opening, rated to 20 kN, for EN 1324 Fig. 2

UGC-SF-200 Bolt and Pin Shear Platens

UGC-SF-200 Bolt and Pin Shear Platens

Clevis-mounted steel shear platens for single and double shear testing of bolts and pins in tension mode, with interchan

UGC-SF-190 Reinforced Concrete Shear Fixture DIN 488

UGC-SF-190 Reinforced Concrete Shear Fixture DIN 488

Weld shear fixtures for reinforcing steel lattice girders and welded wire fabric, bar diameters 3–32 mm and capacities f

Dispersion Adhesive Shear Fixture EN 1324 FAQ

Which test figures does this fixture cover?

EN 1324 Fig. 3, EN 12003 Fig. 3, ISO 13007-2 Fig. 10 and EN 12004-2 Fig. 4.

 

How is it different from UGC-SF-220?

UGC-SF-220 covers the compression arrangement of EN 1324 Fig. 2 and ISO 13007-2 Fig. 9, plus ANSI A118.1. This fixture covers the Fig. 3 / Fig. 10 arrangement.

 

What is the maximum load?

20 kN (4,496 lbf).

 

Why nickel-coated steel?

The coating protects the fixture from moisture and alkaline residue from cementitious and water-based specimens.

 

What coupling does it have?

A female clevis with a Ø 15.9 mm (5/8 in) pin. Other couplings and adapters are available on request.

 

Which machine should I use?

A 25 kN benchtop machine covers the full rating; see our universal testing machines for other sizes.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page