Tile Adhesive Shear Fixture EN 12003

Compression shear fixture for tile adhesives and mortars with a 12–45 mm jaw opening, rated to 20 kN, for EN 1324 Fig. 2, ANSI A118.1 and EN 12003.

Brand: Universal Grip  |  Model: UGC-SF-220  |  ● Configured to order

  • Compression shear for EN 1324 Fig. 2, ANSI A118.1, EN 12003 and ISO 13007-2 Fig. 9

  • 12–45 mm (0.47–1.77 in) jaw opening for different tile and substrate thicknesses

  • Rated to 20 kN (4,496 lbf) maximum test load

  • Rigid 13.15 kg nickel-plated steel body

  • Standard 0 to +70 °C version; special version for -40 to +100 °C

  • Ø 15.9 mm (5/8 in) female clevis; Ø 56 mm upper platen ordered separately

Standards: EN 12003  ·  EN 1324  ·  ANSI A118.1  ·  ISO 13007-2

Trusted by Global Companies

Compression shear testing of tile adhesives and mortars

The UGC-SF-220 is for tile setting material manufacturers and construction labs that measure how well an adhesive or mortar holds a tile in shear. It covers both the European and ISO classification methods (EN 1324 Fig. 2, NF EN 12003, ISO 13007-2 Fig. 9) and ANSI A118.1, the US specification for dry-set cement mortar, so one fixture can serve a lab that tests for both markets.

 

How it works

The bonded specimen is clamped in the fixture, whose jaw opening adjusts from 12 to 45 mm (0.47 to 1.77 in) to suit different tile and substrate thicknesses. An upper compression platen then pushes down on the free tile until the adhesive layer fails in shear. The 13.15 kg nickel-plated steel body is built rigid for its 20 kN (4,496 lbf) rating, which keeps the tile square to the platen as the load rises.

The fixture connects with a female clevis with a Ø 15.9 mm (5/8 in) pin; other couplings are available on request. The Ø 56 mm upper compression platen is a required accessory and is ordered separately from our compression platens.

 

Standard and temperature versions

  • Standard version – 0 to +70 °C (32 to 158 °F), for tests at laboratory conditions after the specimen has been conditioned.

  • Temperature version – -40 to +100 °C (-40 to 212 °F), for labs that test shear strength at low or elevated temperature in an environmental chamber.

 

Machine fit

A 25 kN benchtop universal testing machine covers the full rating. For other frames, adapters are available. Specify the specimen size, test temperature range and machine coupling when ordering.

 

Typical applications

  • Ceramic tile adhesives

  • Cementitious dry-set mortars

  • Dispersion adhesives

  • Building materials testing and certification labs

 

Related tile adhesive fixture

For the arrangement of EN 1324 Fig. 3, EN 12003 Fig. 3 and ISO 13007-2 Fig. 10, use UGC-SF-210, the dispersion adhesive shear fixture. More options are on our shear fixtures and adhesives testing pages. Tell us your standard, specimen size and test temperatures, and we will quote the fixture with the matching platen.

Product video

At a glance

  • Test type: Shear, compression mode

  • Max. load: 20 kN (4,496 lbf)

  • Jaw opening: 12–45 mm

  • Coupling: Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

  • Material: Steel, nickel-plated

  • Temperature range: 0 … +70 °C; -40 … +100 °C version

Tile Adhesive Shear Fixture EN 12003 Specifications

TEST TYPE

Shear, compression mode

 

MAX. LOAD

20 kN (4,496 lbf)

 

JAW OPENING

12–45 mm

 

COUPLING

Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

 

MATERIAL

Steel, nickel-plated

 

TEMPERATURE RANGE

0 … +70 °C; -40 … +100 °C version

 

WEIGHT

13.15 kg

 

ACCESSORY

Upper compression platen Ø 56 mm (not included)

 

STANDARDS

EN 1324 Fig. 2, ANSI A118.1, EN 12003, ISO 13007-2 Fig. 9

 

DRAWINGS

Dimensional drawings on data sheet; 3D models on request

 

PART REF.

UGC-SF-220

 

Models & Options

  • Standard version — 0 … +70 °C (Specify at order)

  • Temperature version — -40 … +100 °C (Specify at order)

  • Upper compression platen Ø 56 mm — Required accessory, ordered separately (On request)

  • Other couplings — Alternatives to the Ø 15.9 mm female clevis (On request)

What's Included

  • 1 tile adhesive shear fixture with Ø 15.9 mm female clevis coupling

  • Upper compression platen Ø 56 mm not included – order separately

Supported Test Standards

  • EN 12003 — Adhesives for tiles – shear adhesion strength of reaction resin adhesives

  • EN 1324 — Adhesives for tiles – shear adhesion strength of dispersion adhesives

  • ANSI A118.1 — Dry-set cement mortar for tile installation

  • ISO 13007-2 — Ceramic tiles – grouts and adhesives – test methods for adhesives

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-210 Dispersion Adhesive Shear Fixture EN 1324

UGC-SF-210 Dispersion Adhesive Shear Fixture EN 1324

Shear adhesion fixture for dispersion and tile adhesives, rated to 20 kN, for EN 1324 Fig. 3, EN 12003 Fig. 3 and ISO 13

UGC-SF-230 V-Notched Beam Shear Fixture

UGC-SF-230 V-Notched Beam Shear Fixture

Iosipescu V-notched beam shear fixture for composite laminates, rated to 50 kN, with the compression probe and specimen

UGC-SF-200 Bolt and Pin Shear Platens

UGC-SF-200 Bolt and Pin Shear Platens

Clevis-mounted steel shear platens for single and double shear testing of bolts and pins in tension mode, with interchan

UGC-SF-240 Plastics Shear Punch Fixture

UGC-SF-240 Plastics Shear Punch Fixture

Punch-tool shear fixture for plastic sheet to ASTM D732 that cuts a 25.4 mm disk, offered as a 20 kN clevis version or a

Tile Adhesive Shear Fixture EN 12003 FAQ

Which standards is the fixture used for?

Tile adhesive shear tests such as EN 1324 Fig. 2, NF EN 12003, ISO 13007-2 Fig. 9 and ANSI A118.1.

 

Can I use it for ANSI A118.1 dry-set mortar testing?

Yes. ANSI A118.1 is one of the methods the fixture is built for, alongside the European and ISO tile adhesive standards.

 

What tile thicknesses fit?

The jaw opening adjusts from 12 to 45 mm (0.47 to 1.77 in).

 

Is the upper platen included?

No. The Ø 56 mm upper compression platen is a required accessory ordered separately.

 

Can I test at low or high temperature?

Yes, a special version covers -40 to +100 °C for use in an environmental chamber. The standard version is rated 0 to +70 °C.

 

What about EN 1324 Fig. 3?

That arrangement is covered by UGC-SF-210, our dispersion adhesive shear fixture.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page