Spinal Implant Compression-Shear Fixture – ASTM F2077, 50 kN

Compression-shear fixture for intervertebral body fusion devices to ASTM F2077, with an inclined loading block and a graduated sliding base.

Brand: Universal Grip  |  Model: UGC-SF-280  |  ● Configured to order

  • Built for ASTM F2077 compression-shear testing of intervertebral body fusion devices

  • Inclined loading block applies combined compression and shear to the implant

  • Graduated sliding base for exact, recordable implant alignment

  • Rated to 50 kN (11,240 lbf) maximum test load

  • Hardened stainless steel construction for implant test environments

  • Ø 20 mm female clevis or M14 x 40 mm thread versions

Standards: ASTM F2077

Trusted by Global Companies

Compression-shear fixture for spinal fusion cages

The UGC-SF-280 is a compression-shear fixture for medical device labs testing intervertebral body fusion devices, such as spinal fusion cages, to ASTM F2077. It gives orthopedic implant developers and contract test labs a dedicated, hardened setup that positions each implant the same way, test after test.

 

How it works

The implant sits on a lower block that is mounted on a graduated sliding base. An inclined upper loading block bears down on the implant, so the machine's vertical load is resolved into combined compression and shear at the device. The graduated scale on the sliding base lets the operator move the lower block until the implant is centered under the load line, and then record that position so every specimen in a series is set up identically.

Typical users include spinal implant developers checking a new cage design, contract labs running F2077 series for customers, and university groups studying orthopedic implants. Because the inclined block and sliding base give a fixed, documented geometry, results from different operators and different days stay comparable.

 

Static and dynamic programs

The fixture is made of hardened stainless steel and suits both static and dynamic implant testing. When you order, tell us which you plan to run, along with the implant size and footprint, so we can confirm the configuration for your test frame and protocol.

 

Versions

  • Ø 20 mm clevis version: female clevis for a Ø 20 mm (0.79 in) pin.

  • M14 thread version: M14 x 40 mm thread connection.

Both versions are rated to 50 kN (11,240 lbf) and are used at ambient temperature.

 

Machine fit

For static compression-shear tests, a 50 kN benchtop universal testing machine matches the fixture's rating. Dynamic programs need a frame capable of cyclic loading; let us know which machine you run and we will confirm the coupling. Where the connection differs from the Ø 20 mm clevis or M14 thread, our adapters can bridge it.

For other compression tooling, including platens and custom compression fixtures, see our compression fixtures page.

Send us the implant size and footprint, whether you are testing static or dynamic, and your machine coupling, and we will prepare a quote.

Product video

At a glance

  • Test type: Compression-shear of intervertebral fusion devices

  • Max. load: 50 kN (11,240 lbf)

  • Loading: Inclined block, combined compression and shear

  • Alignment: Graduated sliding base

  • Coupling: Female clevis Ø 20 mm pin, or M14 x 40 mm thread

  • Material: Stainless steel, hardened

Spinal Implant Compression-Shear Fixture Specifications

TEST TYPE

Compression-shear of intervertebral fusion devices

 

MAX. LOAD

50 kN (11,240 lbf)

 

LOADING

Inclined block, combined compression and shear

 

ALIGNMENT

Graduated sliding base

 

COUPLING

Female clevis Ø 20 mm pin, or M14 x 40 mm thread

 

MATERIAL

Stainless steel, hardened

 

TEMPERATURE RANGE

Ambient

 

TEST MODE

Static or dynamic (specify at order)

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-SF-280

 

Models & Options

  • Ø 20 mm clevis version — Female clevis, Ø 20 mm pin (Specify at order)

  • M14 thread version — M14 x 40 mm thread connection (Specify at order)

  • Coupling adapters — For other machine connections (On request)

What's Included

  • Inclined upper loading block

  • Lower implant block on a graduated sliding base

  • Machine connection per version: Ø 20 mm female clevis or M14 x 40 mm thread

Supported Test Standards

  • ASTM F2077 — Test methods for intervertebral body fusion devices

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-270 O-Ring Composite Shear Fixture

UGC-SF-270 O-Ring Composite Shear Fixture

Special shear fixture for ring-shaped composite samples 70 to 170 mm in diameter, with stepped seats on two steel blocks

UGC-SF-290 Plastic-Metal Assembly Adhesion Fixture ISO 19095-3

UGC-SF-290 Plastic-Metal Assembly Adhesion Fixture ISO 19095-3

Tensile adhesion fixture for plastic-metal assemblies to ISO 19095-3, Fig. 1, with a lever-operated roller grip and an a

UGC-SF-260 Kramer Shear Cell for Food

UGC-SF-260 Kramer Shear Cell for Food

Ten-blade Kramer shear-compression cell for measuring the firmness of fruit, vegetables, meat and processed foods, rated

UGC-SF-300 Sapphire Glue Strength Shear Fixture

UGC-SF-300 Sapphire Glue Strength Shear Fixture

Special shear fixture for measuring the glue strength of bonded sapphire parts, with a rigid housing and inspection wind

Spinal Implant Compression-Shear Fixture FAQ

Which standard is this fixture for?

ASTM F2077 compression-shear testing of intervertebral body fusion devices.

 

How is combined compression and shear produced?

An inclined loading block bears on the implant, so the vertical machine load acts on the device as combined compression and shear.

 

How do I align the implant?

The lower block sits on a graduated sliding base. Slide it until the implant is centered, then note the scale reading to repeat the setup.

 

Can it be used for dynamic testing?

Yes, the fixture suits both static and dynamic implant testing. Tell us which you plan to run and on which frame.

 

Which couplings are available?

A Ø 20 mm female clevis or an M14 x 40 mm thread. Other connections via adapters.

 

What implant sizes does it fit?

Specify your implant size and footprint at order and we will confirm the fixture configuration.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page