top of page

Home  ›  Products  ›  Shear Fixtures  ›  Sapphire Glue Strength Shear Fixture

UGC-SF-300 sapphire glue strength shear fixture with rectangular housing and inspection window by Universal Grip
UGC-SF-300 sapphire glue strength shear fixture with rectangular housing and inspection window by Universal Grip
UGC-SF-300 Sapphire Glue Strength Shear Fixture by Universal Grip, view 2
Product photo 3
Product photo 4

Sapphire Glue Strength Shear Fixture – 10 kN

Special shear fixture for measuring the glue strength of bonded sapphire parts, with a rigid housing and inspection window, rated to 10 kN.

Brand: Universal Grip  |  Model: UGC-SF-300  |  ● Configured to order

  • Designed for shear testing of glue bonds on sapphire components

  • Rigid rectangular housing supports the bonded assembly during the test

  • Inspection window lets you see the specimen and glue line

  • Rated to 10 kN (2,248 lbf) maximum test load

  • Nickel-plated steel with a Ø 25 mm (0.98 in) male clevis coupling

Downloads and standards

Trusted by Global Companies

Shear fixture for bonded sapphire parts

The UGC-SF-300 measures the glue strength of bonded sapphire parts in shear. It is intended for manufacturers and adhesive suppliers working with sapphire cover glass, optical components and consumer electronics assemblies, where the bond between the sapphire and its mating part has to be qualified before production or checked as part of incoming inspection.

 

How it works

The bonded assembly is held in a rigid rectangular housing, and the shear load is applied across the glue line as the machine moves. The stiff housing keeps the part supported so the force goes into the bond rather than into flexing the holder. An inspection window in the housing lets the operator see the specimen and the glue line while positioning it, and look at the failed bond before the part is removed.

Typical uses include comparing candidate adhesives for a cover window, checking the effect of a change in cure process, and verifying production bonds against a minimum shear value. With the same housing and setup for every part, differences in the result point to the bond rather than to the fixture.

 

Capacity and coupling

  • Max. load: 10 kN (2,248 lbf)

  • Coupling: male clevis with a Ø 25 mm (0.98 in) pin hole

  • Material: nickel-plated steel for corrosion resistance

  • Temperature: ambient; other ranges on request

 

Configured to your part

Sapphire parts vary widely in outline, thickness and bond area, so the fixture is set up around your component. When you request a quote, send the part geometry and the bond area; dimensional drawings and 3D models of the fixture are available on request, and custom versions can be made where your part needs a different housing.

 

Machine fit

A 10 kN benchtop universal testing machine covers the full rating. For smaller bond areas where failure loads stay lower, a Mark-10 F-series motorized tester (100–1,500 lbF, up to 6.7 kN) is a compact alternative; its coupling connects through one of our adapters.

For adhesive bonds between other rigid substrates, compare the UGC-SF-170 block-shear fixture and our adhesive testing range.

Tell us the part geometry, bond area and machine coupling, and we will quote the fixture.

Product video

At a glance

  • Test type: Shear of glue bonds

  • Max. load: 10 kN (2,248 lbf)

  • Specimens: Bonded sapphire parts

  • Specimen holder: Rigid rectangular housing with inspection window

  • Coupling: Male clevis, Ø 25 mm pin hole

  • Material: Steel, nickel-plated

Sapphire Glue Strength Shear Fixture Specifications

TEST TYPE

Shear of glue bonds

 

MAX. LOAD

10 kN (2,248 lbf)

 

SPECIMENS

Bonded sapphire parts

 

SPECIMEN HOLDER

Rigid rectangular housing with inspection window

 

COUPLING

Male clevis, Ø 25 mm pin hole

 

MATERIAL

Steel, nickel-plated

 

TEMPERATURE RANGE

Ambient (other ranges on request)

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-SF-300

 

Models & Options

  • Standard fixture — Rectangular housing with inspection window, Ø 25 mm male clevis (Specify at order)

  • Part-specific housing — Adapted to your part geometry and bond area (On request)

  • Coupling adapters — For machines without a Ø 25 mm clevis (On request)

  • Other temperature ranges — Beyond ambient (On request)

What's Included

  • Shear fixture with rigid rectangular specimen housing and inspection window

  • Male clevis coupling with Ø 25 mm pin hole

Supported Test Standards

Standards list

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-170 Adhesive Shear Strength Fixture ISO 13445

UGC-SF-170 Adhesive Shear Strength Fixture ISO 13445

Block-shear fixture for adhesive bonds between rigid substrates, rated to 20 kN, with interchangeable inserts for ASTM D

UGC-SF-290 Plastic-Metal Assembly Adhesion Fixture ISO 19095-3

UGC-SF-290 Plastic-Metal Assembly Adhesion Fixture ISO 19095-3

Tensile adhesion fixture for plastic-metal assemblies to ISO 19095-3, Fig. 1, with a lever-operated roller grip and an a

UGC-SF-310 Dental Restorative Bond Shear Fixture ISO 29022

UGC-SF-310 Dental Restorative Bond Shear Fixture ISO 29022

Notched-edge shear fixture for the bond strength of dental restoratives to tooth structure, with a V-block specimen hold

UGC-SF-280 Spinal Implant Compression-Shear Fixture

UGC-SF-280 Spinal Implant Compression-Shear Fixture

Compression-shear fixture for intervertebral body fusion devices to ASTM F2077, with an inclined loading block and a gra

Sapphire Glue Strength Shear Fixture FAQ

What does the UGC-SF-300 measure?

The glue strength in shear of bonded sapphire parts, such as cover glass and optical components.

 

Why does the housing have a window?

The inspection window lets you see the specimen and glue line while positioning it and check the failed bond after the test.

 

What is the maximum load?

10 kN (2,248 lbf).

 

Will it fit my part?

Send us the part geometry and bond area. The fixture is configured to your component, and custom housings are available on request.

 

Which testing machine do I need?

A 10 kN benchtop UTM covers the full rating; lower-force bonds can run on a Mark-10 F-series tester.

 

How does it connect?

Through a male clevis with a Ø 25 mm pin hole. Other couplings via adapters.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page