Home › Products › Shear Fixtures › Coating Shear Fixture





Coating Shear Fixture – ASTM F1044 / F1160
Shear grips for calcium phosphate and porous metallic implant coatings to ASTM F1044 and F1160, with offset blocks and pinned specimen holders.
Brand: Universal Grip | Model: UGC-SF-320 | ● Configured to order
Built for ASTM F1044 and ASTM F1160 coating shear tests
Offset grip blocks load the coating interface in shear
Pinned specimen holders for quick changeover between specimens
For static and fatigue shear testing of coatings
Nickel-coated steel with a Ø 31.8 mm (1-1/4 in) female clevis
Matching sample preparation fixtures for bonding specimens, up to +200 °C
Standards: ASTM F1044 · ASTM F1160
Trusted by Global Companies


























Shear grips for implant coatings
The UGC-SF-320 shear grips test calcium phosphate and porous metallic coatings to ASTM F1044 and ASTM F1160. Orthopedic and dental implant manufacturers and coating suppliers use them to qualify the bond between a coating and its substrate, whether for process development, lot release or a regulatory test program.
How it works
Two cylindrical substrates are coated and then bonded face to face. Each one is held in an offset grip block, and the blocks are arranged so that, as the machine applies load, the two faces slide past each other and the coating interface fails in shear. The specimen holders are pinned into the blocks, so taking out a broken specimen and loading the next one is quick.
Static and fatigue testing
The grips are used for both static shear tests and shear fatigue programs. Static tests run on a standard universal testing machine; for fatigue work, tell us the frame you plan to use so we can confirm the coupling and configuration. Maximum load is given on request, so include your expected failure load as well, since it sets the frame size for both static and fatigue work.
Sample preparation fixtures
Getting two coated cylinders bonded face to face and in line is as important as the test itself. Matching sample preparation fixtures hold the coated specimens during bonding and can be used up to +200 °C (392 °F). Consistent preparation keeps the two specimens coaxial and the bond line uniform, which reduces scatter in the shear results. Tell us your specimen diameter and length, and how many specimens you prepare per batch, and we will match the preparation fixture.
Construction and coupling
Coupling: female clevis, Ø 31.8 mm (1-1/4 in) pin
Material: nickel-coated steel
Specimens: coated cylindrical substrates
Temperature: ambient
Drawings: dimensional drawings and 3D models on request
The grips fit Galdabini universal testing machines with a Ø 31.8 mm clevis, and our adapters cover other connections. For cyclic programs on other specimen types, see our fatigue grips.
Send us the specimen diameter, whether you are testing static or fatigue, and your machine coupling, and we will quote the grips and any preparation fixtures.
Coating Shear Fixture Specifications
TEST TYPE
Shear of coatings, static and fatigue
MAX. LOAD
On request
SPECIMENS
Coated cylindrical substrates, bonded face to face
GRIP BLOCKS
Offset blocks with pinned specimen holders
COUPLING
Female clevis, Ø 31.8 mm (1-1/4 in) pin
MATERIAL
Steel, nickel-coated
TEMPERATURE RANGE
Ambient
SAMPLE PREPARATION FIXTURES
Optional, for bonding coated specimens, up to +200 °C
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-SF-320
Models & Options
Standard grips — ASTM F1044 / F1160 offset shear blocks, Ø 31.8 mm female clevis (Specify at order)
Sample preparation fixtures — For bonding coated specimens, up to +200 °C (On request)
Coupling adapters — For machines without a Ø 31.8 mm clevis (On request)
What's Included
Pair of shear grips with offset blocks
Pinned specimen holders
Female clevis connections, Ø 31.8 mm pin
Sample preparation fixtures are ordered separately
Supported Test Standards
ASTM F1044 — Shear testing of calcium phosphate and metallic coatings
ASTM F1160 — Shear and bending fatigue testing of calcium phosphate and metallic medical coatings
Compatible Grips & Fixtures
Universal Testing Machines — Galdabini frames for static coating shear
Fatigue Grips — Grips for cyclic test programs
Adapters — Fit the Ø 31.8 mm clevis to other couplings
Shear Testing — Shear methods overview
“Customer quote”
Related Equipment
UGC-SF-310 Dental Restorative Bond Shear Fixture ISO 29022
Notched-edge shear fixture for the bond strength of dental restoratives to tooth structure, with a V-block specimen hold
UGC-SF-330 Tooth Sample Shear Fixture
Compact shear fixture for tooth samples with interchangeable 10 x 10 mm and 5 x 5 mm inserts, knurled side screws and a
UGC-SF-300 Sapphire Glue Strength Shear Fixture
Special shear fixture for measuring the glue strength of bonded sapphire parts, with a rigid housing and inspection wind
UGC-SF-290 Plastic-Metal Assembly Adhesion Fixture ISO 19095-3
Tensile adhesion fixture for plastic-metal assemblies to ISO 19095-3, Fig. 1, with a lever-operated roller grip and an a
Coating Shear Fixture FAQ
Which standards are these grips for?
ASTM F1044 (static shear of calcium phosphate and metallic coatings) and ASTM F1160 (shear fatigue).
How is the specimen loaded?
Two coated cylinders bonded face to face sit in offset blocks, so the applied load shears the coating interface.
Can I run fatigue tests with them?
Yes, the grips are used for static and fatigue shear. Tell us your frame so we can confirm the configuration.
Do you supply fixtures for preparing the specimens?
Yes. Sample preparation fixtures for bonding coated specimens, usable up to +200 °C, are available separately.
What is the maximum load?
On request. Give us your specimen diameter and expected failure load.
How do they connect to my machine?
Through a female clevis with a Ø 31.8 mm (1-1/4 in) pin, or via our adapters.