Plating Embrittlement Shoulder Grip – ASTM F519 Type 1a.2

Shoulder grip with hardened inserts for ASTM F519 type 1a.2 notched round specimens, for sustained-load hydrogen embrittlement tests up to 10 kN.

Brand: Universal Grip  |  Model: UGC-SH-180  |  ● Configured to order

  • Holds ASTM F519 type 1a.2 notched round specimens at their shoulders

  • Inserts with an 8.5 mm (0.335 in) bore and 0.76 mm (0.030 in) seat radius

  • Suited to sustained-load and incremental step-load embrittlement tests

  • Set includes two insert holders and three inserts

  • Rated to 10 kN (2,248 lbf) with a female clevis coupling for a 40 mm pin

Standards: ASTM F519

Trusted by Global Companies

Hydrogen embrittlement testing of plating and coating processes

Electroplating, coating and cleaning processes can introduce hydrogen into high-strength steel, and the resulting embrittlement often shows up only after a part has been under load for some time. ASTM F519 checks a process by loading notched specimens that have gone through it. The UGC-SH-180 is a special shoulder grip for those tests, made for ASTM F519 type 1a.2 notched round specimens. It is used by plating and coating shops, aerospace fastener qualification programs and labs controlling cleaning bath chemistry.

 

How it works

The type 1a.2 specimen is a notched round bar with shoulder heads. Each head sits in a hardened insert with an 8.5 mm (0.335 in) bore and a 0.76 mm (0.030 in) seat radius, so the shoulder bears on a matched radius rather than an edge. The insert sits in an insert holder on each side of the machine. The specimen is then loaded in sustained tension, or in incremental steps, and the test records whether and when it fractures at the notch.

Good seating matters here: a specimen that bends in the grip sees extra stress at the notch and may fail for the wrong reason. The matched seat radius and shoulder loading keep the load axial so the result reflects the process being qualified.

 

What is in the set

  • 2 insert holders with female clevis coupling for a Ø 40 mm (1.57 in) pin

  • 3 inserts, Ø 8.5 mm bore, 0.76 mm seat radius

  • Steel, hardened, nickel-coated

  • Rated to 10 kN (2,248 lbf)

The third insert gives a spare while one is in service; extra inserts can be ordered for labs running many specimens. Frames with a different connection can use our adapters.

 

Machine fit

The 10 kN rating suits a Galdabini 10 kN bench-top universal testing machine, which can hold sustained loads and run incremental step-load profiles under test software control.

 

Related grips

For other small shoulder-head specimens, see our shoulder grips for small specimens and button head grips with split inserts. The full range is on our shoulder grips page, and our metals testing page covers tensile grips for standard metal specimens.

 

Typical applications

Electroplating and coating shops, aerospace fastener qualification, process control of cleaning baths, and high-strength steel parts.

Tell us the ASTM F519 specimen type, how many spare inserts you need and your machine coupling. Request a quote.

Product video

At a glance

  • Max. load: 10 kN

  • Test type: Plating / coating hydrogen embrittlement

  • Specimen: ASTM F519 type 1a.2, shoulder-head round

  • Insert bore: Ø 8.5 mm, seat radius 0.76 mm

  • Coupling: Female clevis, Ø 40 mm pin; others via adapter

  • Material: Steel, hardened, nickel-coated

Plating Embrittlement Shoulder Grip Specifications

MAX. LOAD

10 kN

 

TEST TYPE

Plating / coating hydrogen embrittlement

 

SPECIMEN

ASTM F519 type 1a.2, shoulder-head round

 

INSERT BORE

Ø 8.5 mm, seat radius 0.76 mm

 

COUPLING

Female clevis, Ø 40 mm pin; others via adapter

 

MATERIAL

Steel, hardened, nickel-coated

 

SCOPE OF DELIVERY

2 insert holders, 3 inserts

 

STANDARDS

ASTM F519

 

PART REF.

UGC-SH-180

 

Models & Options

  • ASTM F519 type 1a.2 grip set — 2 insert holders and 3 inserts, Ø 8.5 mm bore, 0.76 mm radius, 10 kN (Specify at order)

  • Spare inserts — Additional Ø 8.5 mm / 0.76 mm inserts (Specify at order)

  • Coupling adapter — For machines without a 40 mm clevis (On request)

What's Included

  • 2 insert holders with female clevis coupling for 40 mm pin

  • 3 inserts with Ø 8.5 mm bore and 0.76 mm seat radius

Supported Test Standards

  • ASTM F519 — Mechanical hydrogen embrittlement evaluation of plating/coating processes

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SH-160 Steel Fastener Grip ISO 898-1 1000 kN

UGC-SH-160 Steel Fastener Grip ISO 898-1 1000 kN

Heavy-duty insert holder for tensile tests on full-size bolts, screws and studs up to 1000 kN, mounted in a larger wedge

UGC-SH-190 Bullet Pull Test Fixture

UGC-SH-190 Bullet Pull Test Fixture

Caliber-specific base holders and matching bullet holders for measuring the force to pull a bullet from its cartridge ca

UGC-SH-150 Rubber Adhesion Test Fixture GOST 209

UGC-SH-150 Rubber Adhesion Test Fixture GOST 209

Cylindrical carriers and 25 mm disc inserts, held by a knurled cross pin, for tear-off adhesion tests of rubber-to-metal

UGC-SH-200 Split Disc Pipe Tensile Fixture

UGC-SH-200 Split Disc Pipe Tensile Fixture

Split disc and split ring fixtures that load a ring cut from plastic or reinforced pipe in hoop tension, rated to 80 kN

Plating Embrittlement Shoulder Grip FAQ

Which specimen does this grip hold?

ASTM F519 type 1a.2 notched round specimens with shoulder heads.

 

What are the insert dimensions?

Each insert has an 8.5 mm (0.335 in) bore and a 0.76 mm (0.030 in) seat radius.

 

What comes in the set?

Two insert holders and three inserts. Extra inserts can be ordered separately.

 

Can it be used for step-load tests?

Yes, it suits both sustained-load and incremental step-load embrittlement tests, up to 10 kN (2,248 lbf).

 

What coupling do the holders use?

Both holders take a 40 mm (1.57 in) clevis pin; an adapter suits other machines.

 

Need help configuring a shoulder and button head grip?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.