UGC-SH-200 split disc pipe tensile fixture with half-disc inserts for ASTM D2290 hoop tensile tests by Universal Grip
UGC-SH-200 split disc pipe tensile fixture with half-disc inserts for ASTM D2290 hoop tensile tests by Universal Grip
UGC-SH-200 Split Disc Pipe Tensile Fixture by Universal Grip, view 2
UGC-SH-200 Split Disc Pipe Tensile Fixture by Universal Grip, view 3
UGC-SH-200 Split Disc Pipe Tensile Fixture by Universal Grip, view 4

Split Disc Pipe Tensile Fixture – ASTM D2290 Hoop Tensile

Split disc and split ring fixtures that load a ring cut from plastic or reinforced pipe in hoop tension, rated to 80 kN or 90 kN.

Brand: Universal Grip  |  Model: UGC-SH-200  |  ● Configured to order

  • Split disc method for ASTM D2290 procedures A, B and C

  • Interchangeable half-disc inserts, R47 x 30 mm and R95 x 30 mm, for different pipe diameters

  • Split disc version rated to 80 kN (about 18,000 lbf)

  • Split ring version with R30 x 25 mm insert for procedure A, rated to 90 kN

  • Hardened, nickel-plated Ø 150 mm disc version for high-volume labs

  • Clevis couplings: female Ø 50 mm on the carrier, male Ø 31.8 mm (1-1/4 in) on the disc version

Standards: ASTM D2290

Trusted by Global Companies

Split disc fixture for hoop tensile testing of plastic and GRP pipe

The UGC-SH-200 measures the apparent hoop tensile strength of rings cut from plastic and reinforced plastic pipe, using the split disc method described in ASTM D2290. It is built for pipe producers, filament-winding shops and independent pipe laboratories that need a repeatable way to load a short ring specimen around its full circumference rather than cutting flat strips from a curved wall.

 

How it works

The ring specimen is slipped over two half-discs. One half is attached to the upper crosshead and one to the lower, so when the testing machine moves the halves apart the ring is stretched in hoop tension and fails at its weakest section. Because the ring wraps the discs, the load is shared by two cross-sections and no clamping force is applied to the pipe wall.

 

Versions and inserts

  • Split disc, procedures A, B and C: a carrier with female clevis Ø 50 mm and half-disc inserts R47 x 30 mm and R95 x 30 mm, rated to 80 kN (about 18,000 lbf).

  • Split disc Ø 150 mm: a hardened, nickel-plated disc with a male clevis and Ø 31.8 mm (1-1/4 in) pin hole, for labs that run high volumes.

  • Split ring, procedure A: carrier and insert R30 x 25 mm, rated to 90 kN (about 20,200 lbf).

  • Inserts only: extra R47 or R95 mm half-discs, 30 mm thick, to extend an existing carrier to another pipe size.

The carrier stays on the machine and only the inserts change between pipe diameters, which keeps setup time short when a lab tests several product lines.

 

Typical applications

The fixture suits plastic and GRP pipe production control, reinforced thermosetting resin pipe, qualification of filament-wound pipe, and contract plastics testing labs. For tensile tests on dumbbells machined from the pipe wall, see the pipe tensile test grips UGC-SH-070.

 

Choosing a testing machine

At 80–90 kN the fixture needs a frame with matching capacity, such as our 100 kN benchtop testing machine or a floor-standing universal testing machine. Galdabini universal testing machines cover 2.5 kN to 2,000 kN, so a frame can be sized to your largest ring. If your crosshead uses a different pin or thread, adapters are available.

Send us the pipe inside diameter, ring width, D2290 procedure, expected peak load and your machine coupling, and we will specify the carrier and insert set.

Product video

At a glance

  • Max. load: 80 kN (split disc); 90 kN (procedure A split ring)

  • Test type: Apparent hoop tensile strength of pipe rings

  • Insert radius: 30 mm, 47 mm or 95 mm

  • Insert thickness: 25 mm or 30 mm

  • Disc diameter: 150 mm (single-disc version)

  • Material: Steel; hardened, nickel-plated version available

Split Disc Pipe Tensile Fixture Specifications

MAX. LOAD

80 kN (split disc); 90 kN (procedure A split ring)

 

TEST TYPE

Apparent hoop tensile strength of pipe rings

 

INSERT RADIUS

30 mm, 47 mm or 95 mm

 

INSERT THICKNESS

25 mm or 30 mm

 

DISC DIAMETER

150 mm (single-disc version)

 

MATERIAL

Steel; hardened, nickel-plated version available

 

COUPLING

Female clevis, Ø 50 mm pin, or male clevis, Ø 31.8 mm (1-1/4 in) pin hole

 

OPERATION

Manual

 

STANDARD

ASTM D2290

 

PART REF.

UGC-SH-200

 

Models & Options

  • Name — Description (Part #)

  • Split disc fixture, procedures A, B, C — Carrier with female clevis Ø 50 mm, half-disc inserts R47 x 30 mm and R95 x 30 mm, 80 kN (Specify at order)

  • Split disc Ø 150 mm — Hardened, nickel-plated disc, male clevis Ø 31.8 mm (1-1/4 in) pin hole (Specify at order)

  • Split ring, procedure A — Carrier and insert R30 x 25 mm, 90 kN (Specify at order)

  • Half-disc inserts only — R47 or R95 mm, 30 mm thick, for an existing carrier (On request)

What's Included

  • Split disc version: carrier with female clevis Ø 50 mm and the half-disc inserts selected at order

  • Split ring version: carrier with R30 x 25 mm insert

  • Additional half-disc inserts are ordered separately

  • Machine adapters, if your coupling differs, are quoted separately

Supported Test Standards

  • ASTM D2290 — Apparent hoop tensile strength of plastic or reinforced plastic pipe

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SH-070 Pipe Tensile Test Grips ISO 6259-3

UGC-SH-070 Pipe Tensile Test Grips ISO 6259-3

Shoulder grips for dumbbell specimens machined from thermoplastic pipe walls, in two versions for 12 to 50 mm and 30 to

UGC-SH-190 Bullet Pull Test Fixture

UGC-SH-190 Bullet Pull Test Fixture

Caliber-specific base holders and matching bullet holders for measuring the force to pull a bullet from its cartridge ca

UGC-SH-210 Withdrawal Resistance Test Fixture

UGC-SH-210 Withdrawal Resistance Test Fixture

Open-cage upper grips with slotted, interchangeable inserts for withdrawal and pull-through tests on anchors, fasteners

UGC-SH-180 Plating Embrittlement Shoulder Grip

UGC-SH-180 Plating Embrittlement Shoulder Grip

Shoulder grip with hardened inserts for ASTM F519 type 1a.2 notched round specimens, for sustained-load hydrogen embritt

Split Disc Pipe Tensile Fixture FAQ

What does a split disc fixture measure?

It measures the apparent hoop tensile strength of a ring cut from pipe. Two half-discs inside the ring are pulled apart, loading the ring in hoop tension until it fails.

 

Which ASTM D2290 procedures does the UGC-SH-200 cover?

The split disc version covers procedures A, B and C. The split ring version, with an R30 x 25 mm insert and 90 kN rating, is intended for procedure A specimens.

 

Can one carrier test several pipe diameters?

Yes. The carrier accepts interchangeable half-disc inserts (R47 and R95 mm, 30 mm thick), so you change inserts rather than the whole fixture. Other radii can be discussed at quote.

 

What load capacity do I need on my testing machine?

The split disc fixture is rated to 80 kN (about 18,000 lbf) and the split ring to 90 kN (about 20,200 lbf). A 100 kN benchtop testing machine or larger frame is a sensible match.

 

How does the fixture connect to my machine?

The carrier uses a female clevis with a Ø 50 mm pin; the Ø 150 mm disc version has a male clevis with a Ø 31.8 mm (1-1/4 in) pin hole. Other couplings are handled with adapters.

 

What information do you need for a quote?

Pipe inside diameter, ring width, the D2290 procedure, the expected maximum load and your machine coupling. Contact us and we will configure the fixture.

 

Need help configuring a shoulder and button head grip?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page