top of page

Home  ›  Products  ›  Compression Platens  ›  Heated Compression Platen 280 °C

UGC-CP-030 heated compression platen 280 °C with Ø 150 mm face and temperature controller by Universal Grip
UGC-CP-030 heated compression platen 280 °C with Ø 150 mm face and temperature controller by Universal Grip
UGC-CP-030 Heated Compression Platen 280 C by Universal Grip, view 2
Product photo 3
Product photo 4

Heated Compression Platen 280 °C – Ø 150 mm, 20 kN

Electrically heated Ø 150 mm compression platen with its own controller, for compression tests up to 280 °C and 20 kN without a full chamber.

Brand: Universal Grip  |  Model: UGC-CP-030  |  ● Configured to order

  • Heats the specimen directly through the platen, from ambient to +280 °C (536 °F)

  • Ø 150 mm (5.9 in) loading face rated to 20 kN (about 4,496 lbf)

  • Separate digital controller shows setpoint and actual temperature

  • Perforated stainless steel guard around the heated platen

  • Mounts on the testing machine like a standard compression platen

  • Elevated-temperature compression without a full environmental chamber

Downloads and standards

Trusted by Global Companies

Heated compression platen for elevated-temperature tests

Many materials behave differently once they are warm. Thermoplastics soften, elastomers relax and adhesives creep, so a compression result taken at room temperature may say little about a part that runs hot in service. The UGC-CP-030 heats the specimen directly through a Ø 150 mm (5.9 in) steel platen, from ambient up to +280 °C (536 °F), at loads up to 20 kN (about 4,496 lbf). It is aimed at polymer, adhesive and composite labs that need temperature-dependent compression data but do not want to commit to a full environmental chamber.

 

How it works

Electric heating elements bring the platen to a temperature you set on a separate digital controller. The controller shows both the setpoint and the actual value, so the operator can see when the platen has stabilized before starting the test. Heat passes into the specimen through the contact face, which makes this approach well suited to thin or flat specimens that warm through quickly. A perforated stainless steel guard surrounds the heated platen to reduce the chance of accidental contact while still letting air circulate.

Mechanically, the heated platen mounts on the testing machine like a standard compression platen. The machine coupling is made to suit your frame and is specified at order, and the controller is built for the supply voltage you give us.

 

Typical applications

  • Thermoplastics and elastomers tested near their service or processing temperature (see plastics and elastomers)

  • Adhesives and sealants whose compressive response changes with heat

  • Composite and molded parts

  • Any compression test where the result depends on temperature

 

Heated platen or chamber?

A heated platen warms the specimen from the contact face. If the whole specimen, fixture and surrounding air must sit at one uniform temperature, or you need sub-ambient conditions, an environmental chamber is the better tool. Unheated alternatives are listed on our compression platens page.

For the load frame, a Galdabini 25 kN benchtop universal testing machine covers the platen's 20 kN rating with some margin. Couplings for other frames are available through our adapters.

Tell us your machine coupling, the highest temperature you need and your controller supply voltage, and we'll quote the heated platen configured for your setup.

Product video

At a glance

  • Max. load: 20 kN

  • Test type: Compression at elevated temperature

  • Platen diameter: 150 mm

  • Temperature range: Ambient to +280 °C

  • Heating: Electric, with external temperature controller

  • Controller display: Setpoint and actual value

Heated Compression Platen 280 °C Specifications

MAX. LOAD

20 kN

 

TEST TYPE

Compression at elevated temperature

 

PLATEN DIAMETER

150 mm

 

TEMPERATURE RANGE

Ambient to +280 °C

 

HEATING

Electric, with external temperature controller

 

CONTROLLER DISPLAY

Setpoint and actual value

 

MATERIAL

Steel platen, stainless steel guard

 

COUPLING

On request

 

POWER SUPPLY

On request

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-CP-030

 

Models & Options

  • Machine coupling — Made to suit your testing machine (Specify at order)

  • Controller supply voltage — Controller built for your mains supply (Specify at order)

  • Maximum test temperature — Tell us the highest temperature you need, up to 280 °C (Specify at order)

  • Coupling adapters — For mounting on an existing machine coupling (On request)

What's Included

  • Electrically heated Ø 150 mm steel compression platen

  • Perforated stainless steel guard around the heated platen

  • Separate digital temperature controller with setpoint and actual-value display

  • Machine coupling as specified at order

Supported Test Standards

Standards list

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-CP-020 Rectangular Steel Compression Platen 100 x 200 mm

UGC-CP-020 Rectangular Steel Compression Platen 100 x 200 mm

Nickel-plated steel compression platen with a 100 x 200 mm loading face, rated to 50 kN, for elongated specimens and sam

UGC-CP-080 Compression Platens for Bag Testing

UGC-CP-080 Compression Platens for Bag Testing

Pair of anodized aluminum platens with slotted clamping bars that hold bags and pouches 0 to 34 mm wide for low-force co

UGC-CP-010 Compression Platens with Guide Bars

UGC-CP-010 Compression Platens with Guide Bars

Anodized aluminum compression platens on ball-bearing guide bars that stay parallel when cartons, boxes or chairs fail o

UGC-CP-100 Compression Spring Test Fixture

UGC-CP-100 Compression Spring Test Fixture

Guide-pin fixture that centers helical springs and stops buckling during compression tests, with pin size and coupling m

Heated Compression Platen 280 °C FAQ

How hot does the platen get?

From ambient up to +280 °C (536 °F), set on the separate digital controller.

 

What load is it rated for?

20 kN, about 4,496 lbf, on a Ø 150 mm loading face.

 

Does it need an environmental chamber?

No. The platen heats the specimen through its contact face. Choose an environmental chamber instead if the whole specimen and fixture must be held at one temperature.

 

How is the temperature controlled?

A separate digital controller drives the electric heating and displays both setpoint and actual temperature.

 

Is there protection against touching the hot platen?

Yes. A perforated stainless steel guard surrounds the heated platen.

 

What do I need to specify when ordering?

Your machine coupling, the maximum temperature you need and the supply voltage for the controller.

 

Need help configuring a compression platen?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page