Home › Products › Shear Fixtures › Ceramic Composite Shear Fixture





Ceramic Composite Shear Fixture – ASTM C1292
Compression shear fixture for notched fiber-reinforced ceramic specimens up to 10 mm thick, rated to 10 kN, for ASTM C1292 Fig. 1 testing.
Brand: Universal Grip | Model: UGC-SF-150 | ● Configured to order
Built for ASTM C1292 Fig. 1 shear testing of fiber-reinforced ceramics
Accepts notched specimens 0–10 mm (up to 0.39 in) thick
Rated to 10 kN (2,248 lbf) maximum test load
Specimen holder and compression probe in nickel-plated steel
Standard 1.35 kg version with Ø 15.9 mm (5/8 in) female clevis
Two-part 0.5 kg version for use between upper and lower platens
Standards: ASTM C1292
Trusted by Global Companies


























Shear strength testing of ceramic matrix composites
The UGC-SF-150 is for materials labs characterizing ceramic matrix composites (CMCs) and other fiber-reinforced ceramics at ambient temperature. It uses the double-notched compression arrangement of ASTM C1292, Fig. 1: a notched specimen stands in the lower specimen holder, an upper probe loads it in compression, and the material fails in interlaminar or in-plane shear on the plane between the two notches. The notch spacing sets the shear area, so the fixture's job is to load the specimen squarely and repeatably.
Fixture design
The holder accepts specimens from 0 to 10 mm (up to 0.39 in) thick. Holder and probe are nickel-plated steel and rated to 10 kN (2,248 lbf). Whether the specimen fails interlaminar or in-plane depends on how it is cut from the laminate, so the same fixture serves both directions.
Two versions
Standard fixture – specimen holder and compression probe with a Ø 15.9 mm (5/8 in) female clevis coupling; 1.35 kg without the lower platen. The lower compression platen is ordered separately.
Two-part fixture – a 0.5 kg version that runs between upper and lower compression platens, for machines already set up for compression work.
Choose the standard version if your load train uses clevis couplings, and the two-part version if your frame already carries compression platens and you would rather not change the set-up between tests.
Machine fit
A 10 kN benchtop universal testing machine matches the fixture rating; labs that also run flexure or tensile tests on composites often choose a 25 kN frame for headroom. We supply the compression platens and any adapters needed. The fixture is specified for 0 to +70 °C; other ranges on request.
Typical applications
Ceramic matrix composites
Fiber-reinforced ceramics in materials research
Aerospace thermal structures
Comparing fiber architectures and interphase coatings
Related composite shear fixtures
For polymer-matrix composites, see UGC-SF-230, the V-notched beam shear fixture (ASTM D5379 guide), and UGC-SF-250, the V-notched rail shear fixture (ASTM D7078 guide). Flexure fixtures for ceramics are on our bend testing fixtures page.
Tell us the specimen thickness, your machine coupling and which platens you already have, and we will quote the complete set-up.
Ceramic Composite Shear Fixture Specifications
TEST TYPE
Shear of notched specimens, compression mode
MAX. LOAD
10 kN (2,248 lbf)
SPECIMEN THICKNESS
0–10 mm
COUPLING
Female clevis, Ø 15.9 mm (5/8 in) pin
MATERIAL
Steel, nickel-plated
TEMPERATURE RANGE
0 … +70 °C (others on request)
WEIGHT
1.35 kg (without lower platen); two-part version 0.5 kg
SCOPE OF DELIVERY
Specimen holder and compression probe
LOWER COMPRESSION PLATEN
Ordered separately
STANDARD
ASTM C1292, Fig. 1
PART REF.
UGC-SF-150
Models & Options
Standard fixture — Holder + probe with Ø 15.9 mm coupling; 1.35 kg (Specify at order)
Two-part fixture — For use between upper and lower platens; 0.5 kg (Specify at order)
Compression platens — Lower platen for the standard fixture; upper and lower for the two-part version (On request)
What's Included
Specimen holder
Compression probe
Lower compression platen not included – order separately (two-part version needs upper and lower platens)
Supported Test Standards
ASTM C1292 — Shear strength of continuous fiber-reinforced advanced ceramics at ambient temperatures
Compatible Grips & Fixtures
Compression platens — Lower platen for the specimen holder
10 kN benchtop machine — Matches the 10 kN fixture rating
25 kN benchtop machine — Headroom for wider composite programs
Bend testing fixtures — Flexural fixtures for ceramics and composites
Shear testing — Overview of shear test methods
“Customer quote”
Related Equipment
UGC-SF-230 V-Notched Beam Shear Fixture
Iosipescu V-notched beam shear fixture for composite laminates, rated to 50 kN, with the compression probe and specimen
UGC-SF-250 V-Notched Rail Shear Fixture
Pair of V-notched rail shear grips for composites to ASTM D7078, in 50 kN and 100 kN versions plus a -100 to +600 °C hig
UGC-SF-140 Shear Fixture with Cardan Joints ISO 1922
Self-aligning shear fixture with two cardan joints for sandwich cores, rigid foams and adhesive joints, in parallel, ang
UGC-SF-160 Plywood Glue Bond Shear Fixture EN 314-1
Compact compression shear fixture with polyamide jaws for checking the glue bond quality of plywood specimens to EN 314-
Ceramic Composite Shear Fixture FAQ
What specimens does the fixture accept?
Double-notched specimens of fiber-reinforced ceramic from 0 to 10 mm thick, as used in ASTM C1292, Fig. 1.
What is the maximum load?
10 kN (2,248 lbf).
Is the lower compression platen included?
No. The standard fixture includes the specimen holder and compression probe; order the lower compression platen separately.
What is the difference between the standard and two-part versions?
The standard version has a Ø 15.9 mm clevis coupling and weighs 1.35 kg. The two-part version weighs 0.5 kg and runs between upper and lower platens.
Can it test at elevated temperature?
It is specified for 0 to +70 °C, matching the ambient-temperature scope of ASTM C1292. Other ranges are available on request.
Do you have shear fixtures for polymer-matrix composites?
Yes, see the V-notched beam fixture UGC-SF-230 and V-notched rail fixture UGC-SF-250.