Home › Products › Shoulder and Button Head Grips › Liquid-Applied Membrane Adhesion Fixture EN 14891





Liquid-Applied Membrane Adhesion Fixture EN 14891 – A.8 / A.2
Guided fixture that opens a crack beneath liquid-applied waterproofing for tiles to EN 14891 A.8, with a tensile adhesion version for A.2.
Brand: Universal Grip | Model: UGC-SH-090 | ● Configured to order
Built for crack-bridging tests to EN 14891 Annex A.8
Guide rods keep both blocks aligned while the crack opens
Clamping plates with wing nuts for tool-free specimen mounting
Hardened, nickel-plated steel for long service life
Crack-bridging version rated 10 kN (2,248 lbf) with 5/8 in clevis
Separate 5 kN tensile adhesion version for EN 14891 Annex A.2
Standards: EN 14891
Trusted by Global Companies


























Testing waterproofing membranes for tiled floors and walls
Liquid-applied waterproofing beneath ceramic tiles has to stay watertight when the substrate below it cracks. EN 14891 sets out how to check that. The UGC-SH-090 is a test fixture for liquid-applied waterproofing products used under tiling, built mainly for the crack-bridging test of EN 14891 Annex A.8. A separate version handles tensile adhesion strength to Annex A.2. Building chemical manufacturers, tile adhesive producers and construction materials labs use it in product development and certification work.
How the crack-bridging fixture works
The coated substrate is clamped between two guided blocks, each with a clamping plate tightened by wing nuts. As the testing machine pulls the blocks apart, the substrate cracks and the gap opens beneath the membrane. Guide rods keep the two blocks aligned the whole time, so the crack opens evenly rather than twisting or peeling the membrane at one corner. The test records how the membrane bridges the widening crack.
Wing-nut clamping means specimens are mounted and removed without tools. The fixture is hardened, nickel-plated steel, rated to 10 kN (2,248 lbf), with a female clevis coupling for a 15.9 mm (5/8 in) pin.
Versions
Crack-bridging, EN 14891 A.8: guided fixture, 10 kN, female clevis Ø 15.9 mm (5/8 in).
Tensile adhesion, EN 14891 A.2: pull-off fixture, 5 kN (1,124 lbf), male clevis Ø 16 mm.
Other couplings are available on request or through our adapters. The standard operating range is 0 to 70 °C, with other ranges on request, which is useful when a test program includes conditioned specimens tested in an environmental chamber.
Machine fit
Both versions suit a Galdabini 10 kN bench-top universal testing machine; the 5 kN adhesion version also fits a 5 kN frame. For pull-off tests on paints and coatings, see the coating bond strength fixture.
Typical applications
Waterproofing membranes under tiles, tile adhesives and building chemicals, construction product certification and building materials laboratories. See also our adhesives testing page.
Tell us which test you need (crack-bridging A.8 or tensile adhesion A.2), your substrate or specimen size and your machine coupling, and we will quote the right fixture. Request a quote.
Product video
At a glance
Max. load: 10 kN (crack-bridging); 5 kN (tensile adhesion)
Test type: Crack-bridging ability; tensile adhesion strength
Material: Steel, hardened, nickel-plated
Coupling: Female clevis, Ø 15.9 mm (5/8 in) pin; others on request
Temperature range: 0 to 70 °C; other ranges on request
Operation: Manual clamping with wing nuts
Liquid-Applied Membrane Adhesion Fixture EN 14891 Specifications
MAX. LOAD
10 kN (crack-bridging); 5 kN (tensile adhesion)
TEST TYPE
Crack-bridging ability; tensile adhesion strength
MATERIAL
Steel, hardened, nickel-plated
COUPLING
Female clevis, Ø 15.9 mm (5/8 in) pin; others on request
TEMPERATURE RANGE
0 to 70 °C; other ranges on request
OPERATION
Manual clamping with wing nuts
SCOPE OF DELIVERY
1 fixture
STANDARDS
EN 14891
PART REF.
UGC-SH-090
Models & Options
Crack-bridging, EN 14891 A.8 — Guided fixture, 10 kN, female clevis Ø 15.9 mm (5/8 in) (Specify at order)
Tensile adhesion, EN 14891 A.2 — Pull-off fixture, 5 kN, male clevis Ø 16 mm (Specify at order)
Other coupling or temperature range — Coupling or temperature range outside the standard (On request)
What's Included
1 fixture in the version ordered
Clamping plates with wing nuts (crack-bridging version)
Dimensional drawings on page 2 of the data sheet; certified drawings and 3D models on request
Supported Test Standards
EN 14891 — Liquid-applied water-impermeable products for use beneath ceramic tiling
Compatible Grips & Fixtures
10 kN universal testing machine — Galdabini frame for both versions
5 kN universal testing machine — For the 5 kN tensile adhesion version
Environmental chambers — For tests outside room temperature
Adhesives testing — Bond and adhesion test fixtures
Adapters — For other machine couplings
“Customer quote”
Related Equipment
UGC-SH-080 Net Holding Fixture 10 kN
Pin-bar fixture pair for tensile tests on nets and open mesh up to 10 kN: meshes hook over a row of pins and a clamping
UGC-SH-100 Adjustable Double Hook Grip
Compact lower grip with two screw-adjusted hook arms for pulling loops, rings and eyelets, connected by an M12 male thre
UGC-SH-070 Pipe Tensile Test Grips ISO 6259-3
Shoulder grips for dumbbell specimens machined from thermoplastic pipe walls, in two versions for 12 to 50 mm and 30 to
UGC-SH-110 Fine Ceramics Tensile Fixture ISO 15490
Steel tensile fixtures for monolithic fine ceramics to ASTM C1273 and ISO 15490, with seats for GIRI, Fig. 15 and Karlsr
Liquid-Applied Membrane Adhesion Fixture EN 14891 FAQ
Which EN 14891 tests does this cover?
The standard fixture is for the crack-bridging test of Annex A.8. A separate pull-off fixture is available for tensile adhesion strength to Annex A.2.
How does the fixture keep the crack even?
Guide rods keep the two clamping blocks aligned as they separate, so the crack opens evenly beneath the membrane.
What are the load ratings?
10 kN (2,248 lbf) for crack-bridging and 5 kN (1,124 lbf) for tensile adhesion.
What couplings do the versions use?
The crack-bridging fixture has a female clevis for a 15.9 mm (5/8 in) pin; the adhesion fixture has a male clevis Ø 16 mm. Other couplings are on request or via adapters.
Can I test at other temperatures?
The standard range is 0 to 70 °C; other ranges are available on request.