Home › Products › Video Extensometers › UGC-VE-2116 16 MPx Single-Camera Video Extensometer





UGC-VE-2116 16 MPx Single-Camera Video Extensometer
16 MPx non-contact optical extensometer, 200 mm all-in-one housing. Maximum field of view for long specimens.
Brand: Universal Grip | Model: UGC-VE-2116 | ● Configured to order
ISO 9513 Class 0.5 measuring length 330 mm; Class 1 660 mm
70 Hz typical sampling, up to 1 kHz with a narrowed view
All-in-one: camera, C-mount lens, blue LED light and USB light relay
Stackable — add camera units to join fields of view
Non-contact: stays on through break, no knife edges
Live output to your test machine (digital, analog, pulse) and API control
Downloads: Video Extensometer Inquiry Form (Excel)
Standards: ASTM D4595 · ASTM D2256 · ASTM D885 · ASTM A615 · ASTM D4632
Trusted by Global Companies


























A maximum-field 16 MPx video extensometer for geotextiles, rope and long specimens
The UGC-VE-2116 is a non-contact optical (video) extensometer from the X-Sight 2000 Series, supplied, configured and supported by Universal Grip. It tracks gauge marks on the specimen with one 16 MPx camera and reports strain, total length, delta length and angle in real time, so it can stay on the specimen through break with no knife edges to slip or damage. Class 0.5 measuring length of 330 mm suits standard dog-bone and strip specimens.
Measuring length, accuracy class and sampling rate
Per ISO 9513 the UGC-VE-2116 measures 330 mm at Class 0.5, 660 mm at Class 1 and 1320 mm at Class 2. Class 0.5 is the tight class labs choose for modulus and proof-strength work; ISO 6892-1 calls for Class 1 or better for yield and proof strength and allows Class 2 for elongation after fracture.
Typical sampling is 70 Hz (23 Hz with the full image), and narrowing the view width raises it to 1 kHz. Higher pixel counts trade frame rate for field of view: at this resolution the camera favours reach and resolution over raw speed.
As a sizing check: the Class 2 measuring length of 1320 mm is long enough to follow a gauge section of about 1.3 m, to measure several gauge lengths on one long specimen, or to watch more than one specimen at once. We confirm the usable field from your specimen, grips and expected elongation.
What the UGC-VE-2116 is best for
wide-width geotextile tests to ASTM D4595 and geogrids
rope, cord and yarn to ASTM D2256 and ASTM D885
rebar and long structural specimens to ASTM A615
large components and several specimens in one field of view
Why a single 200 mm housing
The camera, C-mount lens, 200 mm blue LED (465 nm) and USB light relay are built into one 221 × 187 × 80 mm housing that weighs 1.4 kg. Bolt it to the test frame with two M6 screws on a 165 mm span or put it on a tripod using the 1/4"-20 thread. When your specimens grow, add camera units: the same hardware is the building block of the 2200 and 2300 configurations.
Choosing the lens and working distance
Measuring length, lens focal length and working distance are linked: choose two and the third follows. For the Class 0.5 field of view (330 mm high by 188 mm wide) the working distances are 12 mm lens 262 mm, 16 mm lens 352 mm, 25 mm lens 556 mm, 35 mm lens 782 mm, 50 mm lens 1,122 mm (from the front cover). Longer working distances reduce LED intensity and can need longer shutter times, so tell us your frame and chamber geometry and we will pick the lens.
Connects to your testing machine
Strain is streamed live to the test-machine controller over DOLI Binary, MODBUS, HP Video, TCP/IP or RS232, as an analog signal through auxiliary D/A converters, or as an encoder-style quadrature pulse. The JSON and MRT APIs let your test software start and stop measurement, switch methods and set the gauge length. That is how we retrofit video extensometers to Instron, MTS, ZwickRoell, Shimadzu, Test Resources, ADMET and Galdabini frames; see retrofitting a video extensometer to an existing machine.
Compare the UGC-VE-2116 with similar models
UGC-VE-2109: 2000 Series single-camera, 9 MPx, Class 0.5 220 mm, 75 Hz typical
UGC-VE-2106: 2000 Series single-camera, ASTM-optimized, ASTM E83 Class B-1, 200 Hz typical
UGC-VE-2216: 2000 Series dual-camera, 16 MPx, Class 0.5 640 mm, 70 Hz typical
UGC-VE-2316: 2000 Series triple-camera, 16 MPx, Class 0.5 920 mm, 70 Hz typical
Not sure which model fits? Read how to choose an extensometer, gauge length selection for video extensometers, or compare all models on our video extensometer page.
FULL GUIDE: Video Extensometers for Universal Testing Machines
At a glance
Cameras: 1 × 16 MPx industrial camera
Sampling rate: 70 Hz typical · 23 Hz at full view · up to 1 kHz with reduced view width
Measuring length (ISO 9513): Class 0.5: 330 mm · Class 1: 660 mm · Class 2: 1320 mm
Field of view, Class 0.5 (H × W): 330 × 188 mm
Field of view, Class 1 (H × W): 660 × 376 mm
Field of view, Class 2 (H × W): 1320 × 752 mm
UGC-VE-2116 16 MPx Single-Camera Video Extensometer Specifications
MODEL
UGC-VE-2116 · 2000 Series, single-camera
CAMERAS
1 × 16 MPx industrial camera
SAMPLING RATE
70 Hz typical · 23 Hz at full view · up to 1 kHz with reduced view width
MEASURING LENGTH (ISO 9513)
Class 0.5: 330 mm · Class 1: 660 mm · Class 2: 1320 mm
FIELD OF VIEW, CLASS 0.5 (H × W)
330 × 188 mm
FIELD OF VIEW, CLASS 1 (H × W)
660 × 376 mm
FIELD OF VIEW, CLASS 2 (H × W)
1320 × 752 mm
WORKING DISTANCE
300–500 mm typical from front cover; extendable on request
LENS
C-mount; 12, 16, 25, 35 or 50 mm focal length selected per application
LIGHT
200 mm blue LED (465 nm, 165 lm, 8 W), USB-switched
PC INTERFACE
USB 3.0 per camera (1 total) + USB 2.0 for light relay; 3 m cables standard
DATA OUTPUT
DOLI Binary, MODBUS, HP Video, TCP/IP, RS232; analog via D/A; quadrature pulse; JSON and MRT API
HOUSING DIMENSIONS
221 × 187 × 80 mm (L × W × H)
WEIGHT
1.4 kg
POWER
24 V DC via RJ45 power cable (802.3af Mode B); 12 W
MOUNTING
Tripod 1/4"-20 UNC (center) or 2 × M6 on a 165 mm vertical span
ENVIRONMENT
Indoor; 5–40 °C, 30–70 % RH
SOFTWARE
Windows 10/11 64-bit or Windows Server 2019/2022; perpetual license on USB key
PC REQUIREMENTS
2 GHz dual-core min. (4 GHz, 8+ cores rec.); 4 GB RAM min. (16 GB rec.); OpenGL 3.0
STANDARDS
ISO 9513 accuracy classes; used for ISO 6892-1, ASTM E8 and similar methods
Models & Options
C-mount lens — 12, 16, 25, 35 or 50 mm focal length chosen from your gauge length and working distance (Specify at order)
AX module (included) — Point, Line and Extreme Line probes for axial strain and elongation (AX)
Transverse module — Transverse line and bend line for r-value, Poisson's ratio and deflection (TR)
Torsion / crack module — Torsion line and crack-opening probe (TO / CR)
Rebar module — Rebar line for reinforcing-steel testing (ITT)
DIC / post-processing — DIC area strain mapping and re-analysis of recorded tests (DIC / PP)
High-speed, device input, color — High-speed recorder, external force/temperature/pressure input, color value distribution (HS / DI / LVD)
Accessories — Calibration grids, tripods, polarization kits, PCIe USB 3.0 card, pulse generator, D/A converters (On request)
Sample marking — Gauge-mark marking tools for fast, repeatable marks (Marking tool)
Upgrade path — Add camera units to move to 2200 / 2300 multi-camera configurations (2200 / 2300)
What's Included
VE unit with lens, 200 mm LED & built-in USB relay
Mono calibration grid sized to the application
Cable harness, 24 V power supply
Software on installation USB + USB license key
Axial software module (perpetual license)
1 year software updates & technical support
Supported Test Standards
ASTM D4595 — Wide-width tensile test of geotextiles
ASTM D2256 — Tensile properties of yarns
ASTM D885 — Tire cords and industrial filament yarns
ASTM A615 — Deformed carbon-steel bars for concrete reinforcement
ASTM D4632 — Grab breaking load of geotextiles
Compatible Grips & Fixtures
Universal testing machines — Retrofit to Instron, MTS, ZwickRoell, Shimadzu, Test Resources, ADMET or Galdabini frames
Tensile grips — Wedge, vise, roller and pneumatic grips; the camera views the specimen between them
Environmental chambers — Measure through the chamber window with the right lighting
Marking tool — Repeatable gauge marks for video extensometers
Clip-on extensometers — Contact alternative for single-gauge-length tests
All extensometers — Clip-on, long-travel, video and 3D extensometers
“Customer quote”
Related Equipment
UGC-VE-2109 9 MPx Single-Camera
2000 Series single-camera, 9 MPx
UGC-VE-2106 ASTM
2000 Series single-camera, ASTM-optimized
UGC-VE-2216 16 MPx Dual-Camera
2000 Series dual-camera, 16 MPx
UGC-VE-2316 16 MPx Triple-Camera
2000 Series triple-camera, 16 MPx
UGC-VE-2116 16 MPx Single-Camera Video Extensometer FAQ
What gauge length and field of view does the UGC-VE-2116 cover?
Per ISO 9513, Class 0.5: 330 mm; Class 1: 660 mm; Class 2: 1320 mm. The exact field depends on the lens and working distance, which we pick from your specimen and frame.
Which ISO 9513 class do I need?
ISO 6892-1 calls for Class 1 or better for yield and proof strength and allows Class 2 for elongation after fracture. Many labs use Class 0.5 for modulus. Plastics methods such as ISO 527 set their own accuracy requirements.
How fast does the UGC-VE-2116 sample?
70 Hz typical, 23 Hz with the full image, and up to 1 kHz with a narrowed view width. Data streams to the test machine controller in real time.
Will the UGC-VE-2116 work with my existing testing machine?
Yes, in most cases. It outputs DOLI Binary, MODBUS, HP Video, TCP/IP, RS232, analog via D/A converters or a quadrature pulse, and the JSON/MRT APIs allow remote start/stop and gauge-length setting. Tell us the make and model of your frame and controller. See retrofitting a video extensometer.
Can I add cameras to the UGC-VE-2116 later?
Yes. The 2000 Series is stackable: adding units moves you to the 2200 dual-camera or 2300 triple-camera configuration with a joined field of view.
What software comes with the UGC-VE-2116?
The axial (AX) module with Point, Line and Extreme Line probes, on a perpetual license stored on a USB key, with one year of updates and technical support. Optional modules add transverse strain (r-value, Poisson's ratio), torsion, crack opening, rebar, DIC mapping and post-processing.
How do I mark specimens for a video extensometer?
Use high-contrast dots or lines at the gauge length. Our marking tools and the sample marking guide cover the common methods.
How do I get a quote for the UGC-VE-2116?
Send your material, test standard, specimen size and gauge length, expected elongation, and your testing machine make/model. Use the Request a Quote button, call 978-882-1480, or download the video extensometer inquiry form.