Home › Products › Video Extensometers › UGC-VE-2316 16 MPx Triple-Camera Video Extensometer





UGC-VE-2316 16 MPx Triple-Camera Video Extensometer
16 MPx non-contact optical extensometer, 200 mm all-in-one housing, 3 camera units joined into one field of view. The longest field of view in its series.
Brand: Universal Grip | Model: UGC-VE-2316 | ● Configured to order
ISO 9513 Class 0.5 measuring length 920 mm; Class 1 1900 mm
70 Hz typical sampling, up to 1 kHz with a narrowed view
All-in-one: camera, C-mount lens, blue LED light and USB light relay
Joined fields of view for long or high-elongation specimens
Non-contact: stays on through break, no knife edges
Live output to your test machine (digital, analog, pulse) and API control
Downloads: Video Extensometer Inquiry Form (Excel)
Standards: ASTM D4595 · ASTM D2256 · ASTM D885 · ASTM A615 · ASTM D4632
Trusted by Global Companies


























Three 16 MPx cameras for the longest measuring lengths in the 2000 Series
The UGC-VE-2316 is a non-contact optical (video) extensometer from the X-Sight 2000 Series, supplied, configured and supported by Universal Grip. It tracks gauge marks on the specimen with three 16 MPx cameras and reports strain, total length, delta length and angle in real time, so it can stay on the specimen through break with no knife edges to slip or damage. Stacked camera units are calibrated with a joined grid, nearly doubling the measuring length per added camera.
Measuring length, accuracy class and sampling rate
Per ISO 9513 the UGC-VE-2316 measures 920 mm at Class 0.5, 1900 mm at Class 1 and 3850 mm at Class 2. Class 0.5 is the tight class labs choose for modulus and proof-strength work; ISO 6892-1 calls for Class 1 or better for yield and proof strength and allows Class 2 for elongation after fracture.
Typical sampling is 70 Hz (23 Hz with the full image), and narrowing the view width raises it to 1 kHz. Higher pixel counts trade frame rate for field of view: at this resolution the camera favours reach and resolution over raw speed.
As a sizing check: the Class 2 measuring length of 3850 mm is long enough to follow a gauge section of about 3.9 m, to measure several gauge lengths on one long specimen, or to watch more than one specimen at once. We confirm the usable field from your specimen, grips and expected elongation.
What the UGC-VE-2316 is best for
wide-width geotextiles and geogrids to ASTM D4595
full-size rebar and structural specimens to ASTM A615
rope, cable and webbing
large components, assemblies and several specimens in one view
Three units, one continuous measurement
Three 200 mm units are stacked and calibrated together with a joined grid, so the software treats them as one extensometer. This is the configuration for very long specimens, very high elongation or several gauge lengths measured at once on the same sample.
Choosing the lens and working distance
Measuring length, lens focal length and working distance are linked: choose two and the third follows. For the Class 0.5 field of view (920 mm high by 188 mm wide) the working distances are 12 mm lens 262 mm, 16 mm lens 352 mm, 25 mm lens 556 mm, 35 mm lens 782 mm, 50 mm lens 1,122 mm (from the front cover). Longer working distances reduce LED intensity and can need longer shutter times, so tell us your frame and chamber geometry and we will pick the lens.
Connects to your testing machine
Strain is streamed live to the test-machine controller over DOLI Binary, MODBUS, HP Video, TCP/IP or RS232, as an analog signal through auxiliary D/A converters, or as an encoder-style quadrature pulse. The JSON and MRT APIs let your test software start and stop measurement, switch methods and set the gauge length. That is how we retrofit video extensometers to Instron, MTS, ZwickRoell, Shimadzu, Test Resources, ADMET and Galdabini frames; see retrofitting a video extensometer to an existing machine.
Compare the UGC-VE-2316 with similar models
UGC-VE-2309: 2000 Series triple-camera, 9 MPx, Class 0.5 620 mm, 75 Hz typical
UGC-VE-2305: 2000 Series triple-camera, 5 MPx, Class 0.5 3 × 130 mm, 175 Hz typical
UGC-VE-2116: 2000 Series single-camera, 16 MPx, Class 0.5 330 mm, 70 Hz typical
UGC-VE-2216: 2000 Series dual-camera, 16 MPx, Class 0.5 640 mm, 70 Hz typical
Not sure which model fits? Read how to choose an extensometer, gauge length selection for video extensometers, or compare all models on our video extensometer page.
FULL GUIDE: Video Extensometers for Universal Testing Machines
At a glance
Cameras: 3 × 16 MPx industrial cameras
Sampling rate: 70 Hz typical · 23 Hz at full view · up to 1 kHz with reduced view width
Measuring length (ISO 9513): Class 0.5: 920 mm · Class 1: 1900 mm · Class 2: 3850 mm
Field of view, Class 0.5 (H × W): 920 × 188 mm
Field of view, Class 1 (H × W): 1900 × 376 mm
Field of view, Class 2 (H × W): 3850 × 752 mm
UGC-VE-2316 16 MPx Triple-Camera Video Extensometer Specifications
MODEL
UGC-VE-2316 · 2000 Series, triple-camera
CAMERAS
3 × 16 MPx industrial cameras
SAMPLING RATE
70 Hz typical · 23 Hz at full view · up to 1 kHz with reduced view width
MEASURING LENGTH (ISO 9513)
Class 0.5: 920 mm · Class 1: 1900 mm · Class 2: 3850 mm
FIELD OF VIEW, CLASS 0.5 (H × W)
920 × 188 mm
FIELD OF VIEW, CLASS 1 (H × W)
1900 × 376 mm
FIELD OF VIEW, CLASS 2 (H × W)
3850 × 752 mm
WORKING DISTANCE
300–500 mm typical from front cover; extendable on request
LENS
C-mount; 12, 16, 25, 35 or 50 mm focal length selected per application
LIGHT
3 × 200 mm blue LED (465 nm, 165 lm, 8 W), USB-switched
PC INTERFACE
USB 3.0 per camera (3 total) + USB 2.0 for light relay; 3 m cables standard
DATA OUTPUT
DOLI Binary, MODBUS, HP Video, TCP/IP, RS232; analog via D/A; quadrature pulse; JSON and MRT API
HOUSING DIMENSIONS
221 × 187 × 80 mm (L × W × H) per unit
WEIGHT
1.4 kg per unit
POWER
24 V DC via RJ45 power cable (802.3af Mode B); 12 W per unit
MOUNTING
Tripod 1/4"-20 UNC (center) or 2 × M6 on a 165 mm vertical span
ENVIRONMENT
Indoor; 5–40 °C, 30–70 % RH
SOFTWARE
Windows 10/11 64-bit or Windows Server 2019/2022; perpetual license on USB key
PC REQUIREMENTS
2 GHz dual-core min. (4 GHz, 8+ cores rec.); 4 GB RAM min. (16 GB rec.); OpenGL 3.0
STANDARDS
ISO 9513 accuracy classes; used for ISO 6892-1, ASTM E8 and similar methods
Models & Options
C-mount lens — 12, 16, 25, 35 or 50 mm focal length chosen from your gauge length and working distance (Specify at order)
AX module (included) — Point, Line and Extreme Line probes for axial strain and elongation (AX)
Transverse module — Transverse line and bend line for r-value, Poisson's ratio and deflection (TR)
Torsion / crack module — Torsion line and crack-opening probe (TO / CR)
Rebar module — Rebar line for reinforcing-steel testing (ITT)
DIC / post-processing — DIC area strain mapping and re-analysis of recorded tests (DIC / PP)
High-speed, device input, color — High-speed recorder, external force/temperature/pressure input, color value distribution (HS / DI / LVD)
Accessories — Calibration grids, tripods, polarization kits, PCIe USB 3.0 card, pulse generator, D/A converters (On request)
Sample marking — Gauge-mark marking tools for fast, repeatable marks (Marking tool)
What's Included
3 × VE unit with lens, 200 mm LED & built-in USB relay
Joined calibration grid sized to the application
Cable harness, 24 V power supply
Software on installation USB + USB license key
Axial software module (perpetual license)
1 year software updates & technical support
Supported Test Standards
ASTM D4595 — Wide-width tensile test of geotextiles
ASTM D2256 — Tensile properties of yarns
ASTM D885 — Tire cords and industrial filament yarns
ASTM A615 — Deformed carbon-steel bars for concrete reinforcement
ASTM D4632 — Grab breaking load of geotextiles
Compatible Grips & Fixtures
Universal testing machines — Retrofit to Instron, MTS, ZwickRoell, Shimadzu, Test Resources, ADMET or Galdabini frames
Tensile grips — Wedge, vise, roller and pneumatic grips; the camera views the specimen between them
Environmental chambers — Measure through the chamber window with the right lighting
Marking tool — Repeatable gauge marks for video extensometers
Clip-on extensometers — Contact alternative for single-gauge-length tests
All extensometers — Clip-on, long-travel, video and 3D extensometers
“Customer quote”
Related Equipment
UGC-VE-2309 9 MPx Triple-Camera
2000 Series triple-camera, 9 MPx
UGC-VE-2305 5 MPx Triple-Camera
2000 Series triple-camera, 5 MPx
UGC-VE-2116 16 MPx Single-Camera
2000 Series single-camera, 16 MPx
UGC-VE-2216 16 MPx Dual-Camera
2000 Series dual-camera, 16 MPx
UGC-VE-2316 16 MPx Triple-Camera Video Extensometer FAQ
What gauge length and field of view does the UGC-VE-2316 cover?
Per ISO 9513, Class 0.5: 920 mm; Class 1: 1900 mm; Class 2: 3850 mm. The exact field depends on the lens and working distance, which we pick from your specimen and frame.
Which ISO 9513 class do I need?
ISO 6892-1 calls for Class 1 or better for yield and proof strength and allows Class 2 for elongation after fracture. Many labs use Class 0.5 for modulus. Plastics methods such as ISO 527 set their own accuracy requirements.
How fast does the UGC-VE-2316 sample?
70 Hz typical, 23 Hz with the full image, and up to 1 kHz with a narrowed view width. Data streams to the test machine controller in real time.
Will the UGC-VE-2316 work with my existing testing machine?
Yes, in most cases. It outputs DOLI Binary, MODBUS, HP Video, TCP/IP, RS232, analog via D/A converters or a quadrature pulse, and the JSON/MRT APIs allow remote start/stop and gauge-length setting. Tell us the make and model of your frame and controller. See retrofitting a video extensometer.
When do I need three cameras?
When the specimen elongation or length is beyond what two units can cover, or when you want several gauge lengths on one long specimen. The UGC-VE-2316 reaches 3850 mm at Class 2.
What software comes with the UGC-VE-2316?
The axial (AX) module with Point, Line and Extreme Line probes, on a perpetual license stored on a USB key, with one year of updates and technical support. Optional modules add transverse strain (r-value, Poisson's ratio), torsion, crack opening, rebar, DIC mapping and post-processing.
How do I mark specimens for a video extensometer?
Use high-contrast dots or lines at the gauge length. Our marking tools and the sample marking guide cover the common methods.
How do I get a quote for the UGC-VE-2316?
Send your material, test standard, specimen size and gauge length, expected elongation, and your testing machine make/model. Use the Request a Quote button, call 978-882-1480, or download the video extensometer inquiry form.