Home › Products › Shear Fixtures › Thermal Barrier Profile Shear Fixture EN 14024





Thermal Barrier Profile Shear Fixture EN 14024
10 kN fixture for longitudinal shear of thermally broken metal profiles to EN 14024 Fig. 5, giving shear strength and elasticity constant.
Brand: Universal Grip | Model: UGC-SF-100 | ● Configured to order
Longitudinal shear test of thermal barrier profiles to DIN EN 14024, Fig. 5
Determines both shear strength and elasticity constant
Rated to 10 kN (about 2,248 lbf) maximum test load
Holds the profile so the two metal shells move relative to each other
Corrosion-resistant nickel-coated steel construction
Ø 30 mm female clevis coupling; adapters on request
Standards: EN 14024
Trusted by Global Companies


























Shear fixture for thermally broken window, door and facade profiles
The UGC-SF-100 determines the shear strength and elasticity constant of metal profiles with thermal barrier to DIN EN 14024, Fig. 5. Window, door and curtain wall system makers, profile extruders and insulating bar suppliers use the test to show that the connection between the inner and outer metal shells will carry the shear loads a frame sees in service.
How it works
A thermally broken profile is two metal shells joined by an insulating bar, typically polyamide. The fixture holds a section of profile so that one shell is restrained and the other is pushed along its length. That displaces the shells relative to each other and loads the insulating bar and its crimped or bonded joints in longitudinal shear. The peak force gives the shear strength; the slope of the force-displacement curve in the elastic range gives the elasticity constant, both of which EN 14024 uses to characterize the composite profile.
Construction
The fixture is made of nickel-coated steel for corrosion resistance and a long service life. It is rated to 10 kN (about 2,248 lbf) and connects with a Ø 30 mm (1.18 in) female clevis. Specimen length is set to EN 14024. Because profile cross-sections vary widely between systems, tell us your profile cross-section and specimen length when you order and the fixture is matched to them.
Test temperature
The standard version is for ambient temperature, with other ranges on request. If your program includes conditioned tests at low or high temperature, say so in your inquiry and we will configure the fixture and recommend a suitable environmental chamber for your frame.
Typical applications
Window and door profiles
Facade systems
Thermally broken aluminum
Polyamide insulating bars
Labs typically run the test when introducing a new insulating bar, a new crimping or rolling setup or a new profile series, and as periodic checks on running profile lines.
Machine fit
A Galdabini 10 kN benchtop universal testing machine matches the fixture's rating and gives the displacement resolution the elasticity constant calls for. Where a lab also runs transverse tensile tests on the same profiles, a 25 kN frame leaves room for both. Frames with a different coupling connect through adapters. Send us your profile cross-section, specimen length, test temperatures and machine coupling, and we will configure the fixture: request a quote.
Thermal Barrier Profile Shear Fixture EN 14024 Specifications
TEST TYPE
Longitudinal shear of thermal barrier profiles
ARRANGEMENT
DIN EN 14024, Fig. 5
RESULTS
Shear strength and elasticity constant
MAX. LOAD
10 kN (2,248 lbf)
SPECIMENS
Metal profiles with thermal barrier
SPECIMEN LENGTH
Per EN 14024
COUPLING
Female clevis, Ø 30 mm pin
MATERIAL
Steel, nickel-coated
TEMPERATURE RANGE
Ambient (other ranges on request)
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-SF-100
Models & Options
EN 14024 shear fixture — Matched to your profile cross-section and specimen length (Specify at order)
Non-ambient version — For conditioned tests at other temperatures (On request)
Coupling adapters — For machines without a Ø 30 mm clevis (On request)
What's Included
EN 14024 Fig. 5 shear fixture in nickel-coated steel
Ø 30 mm female clevis coupling
Profile-specific setup agreed at order
Supported Test Standards
EN 14024 — Metal profiles with thermal barrier – mechanical performance, requirements and tests
Compatible Grips & Fixtures
10 kN Benchtop Universal Testing Machine — Galdabini frame matched to the 10 kN rating
25 kN Benchtop Universal Testing Machine — Room for shear and transverse tensile tests
Environmental Chambers — For conditioned tests at other temperatures
Shear Testing — Shear test methods and fixtures
Adapters — Couplings to the Ø 30 mm clevis
“Customer quote”
Related Equipment
UGC-SF-090 Symmetric Shear Fixture EN 12090
Lightweight anodized aluminum shear fixture for sandwich cores and insulation boards to EN 12090 Fig. 2b, loading two sp
UGC-SF-110 Wood Shear Test Fixture EN 13354
5 kN compression shear fixture for wood and bonded solid wood panels to EN 13354, with a 10–60 mm adjustable jaw and Ø 2
UGC-SF-080 Dental Adhesion Shear Fixture ISO TS 11405
Shear fixture for measuring adhesion to tooth structure to ISO/TS 11405, with a cage holder for embedded teeth and a Ø 1
UGC-SF-120 Double Shear Fastener Fixture NASM 1312-13
Compression-mode double shear fixture that cuts fasteners up to 6.3 mm diameter across two planes for NASM 1312-13 shear
Thermal Barrier Profile Shear Fixture EN 14024 FAQ
What does the UGC-SF-100 measure?
The longitudinal shear strength and elasticity constant of metal profiles with thermal barrier, using the arrangement of DIN EN 14024, Fig. 5.
How is the profile loaded?
One metal shell is held while the other is displaced along the profile, loading the insulating bar in longitudinal shear.
What is the maximum load?
10 kN (about 2,248 lbf).
Can it test at low or high temperature?
The standard version is for ambient temperature. Other ranges are on request, used with an environmental chamber.
Will it fit my profile?
Profile cross-sections vary, so tell us yours and the specimen length when ordering and the fixture is matched to it.
Which machine should I use?
A Galdabini 10 kN benchtop machine. The fixture has a Ø 30 mm female clevis, and adapters are available.