top of page
Search
All Posts


Tensile Grip & Fixture Selection Guide
How to choose tensile grips and fixtures that fit Instron, MTS, Shimadzu, ZwickRoell, Tinius Olsen and Mark-10 testing machines, from connection type to jaw faces.
Chris Thomas
Oct 165 min read


ASTM D412 Complete Guide: Rubber Tensile Test Procedure, Dies, Grips, Machines and Extensometers
The complete ASTM D412 guide: specimen dies and dimensions, conditioning, test speed, Method A vs. B, choosing grips and a Mark-10 or Galdabini machine, long-travel and video extensometers, calculations, tensile set and FAQs.
Chris Thomas
Oct 1617 min read


3-Point vs. 4-Point Bend Testing: ASTM D790, D6272 and C1161 Explained
The difference between 3-point and 4-point flexural testing, with spans, speeds, formulas and fixtures for ASTM D790 (plastics), D6272 (4-point plastics) and C1161 (ceramics), plus common mistakes and videos.
Chris Thomas
Oct 156 min read


How to Choose a Universal Testing Machine: Capacity, Frame Type, Software and Accessories (Buyer's Guide)
A practical buyer's guide to universal testing machines: how to size capacity with headroom, single vs. dual column, electromechanical vs. hydraulic, travel and column width, accuracy and calibration, software, accessories, price drivers and when a Mark-10 frame is enough.
Chris Thomas
Oct 146 min read


Types of Extensometers: Clip-On vs. Video vs. Long-Travel vs. 3D DIC (How to Choose)
Contact or non-contact? Compare clip-on, long-travel, 2D video and 3D DIC extensometers: ISO 9513 and ASTM E83 accuracy classes, which type each standard calls for, chamber testing, cost and setup videos.
Chris Thomas
Oct 136 min read


ASTM D638 Specimen Types I–V: Dimensions, Test Speeds, Grips and Extensometers
A practical guide to ASTM D638 tensile testing of plastics: Type I, II, III, IV and V specimen dimensions, which type to use, test speeds, the right grips, extensometer requirements for modulus, cutting dies, common mistakes and D638 vs ISO 527.
Chris Thomas
Oct 127 min read


O-Ring Tensile Testing Equipment: How to Configure a System for ASTM D1414
The exact equipment configuration for tensile testing finished O-rings to ASTM D1414: frame and load cell sizing, the motorized spool fixture, the 500 mm/min speed requirement, software features, elongation calculations and D395 compression set.
Chris Thomas
Oct 118 min read


Textile Testing on a Universal Testing Machine: ASTM D5034, D5035, D751, D3787/D6797 Ball Burst and More
A complete guide to textile testing on a universal testing machine: D5034 grab, D5035 strip, D751 coated fabrics, D3787/D6797 ball burst, tear, seam, yarn, webbing and geotextile tests, with the grips, fixtures and videos for each.
Chris Thomas
Oct 1018 min read


Aerospace Composite Testing: Carbon Fiber Shear Fixtures, Galdabini UTMs and ASTM Methods for the Space Boom
Aerospace and space programs are driving record demand for carbon fiber testing. See our D5379, D7078, D6641, D2344 and open-hole fixtures, programmable Galdabini UTMs, video extensometers, temperature chambers and high-temperature grips.
Chris Thomas
Oct 98 min read


Peel Test Fixtures Guide: 90°, 180°, T-Peel, Floating Roller and Climbing Drum Peel Testing with a Mark-10
A detailed guide to every Universal Grip peel fixture: 90°, 180°, T-peel, floating roller, climbing drum, tape-roll and credit-card peel, plus why a Mark-10 is an economical way to peel test.
Chris Thomas
Oct 813 min read


Temperature Chambers for Universal Testing Machines: A Buyer's Guide to Hot and Cold Testing (-80 °C to +350 °C)
How to choose a temperature chamber for tensile, compression and flexure testing: temperature range, LN2 vs. mechanical cooling, grips and extensometers at temperature, and fitting a chamber to an Instron, MTS, Zwick or Shimadzu frame.
Mark Edwards
Oct 55 min read


Video Extensometer Retrofit: Add Non-Contact Strain Measurement to Your Instron, MTS or Shimadzu Machine
A video extensometer retrofits to the testing machine you already own. How it connects to Instron, MTS, Shimadzu, Zwick and Tinius Olsen frames, which model fits your standards, setup steps, cost and FAQs.
christopherthomasb
Oct 56 min read


Composite Test Fixture Buyer's Guide: ASTM D3039, D5379, D7078, D2344, D6641 and More
Which fixtures does a composites lab actually need? A practical guide to ASTM D3039 tensile grips, D5379 and D7078 shear fixtures, D2344 short-beam, D6641 CLC compression and open-hole fixtures.
christopherthomasb
Oct 34 min read


Mark-10 Test Frame vs. Universal Testing Machine: Which Does Your Lab Need?
Mark-10 force frame or full universal testing machine? Compare capacity, tests, strain measurement and à la carte software so you buy what your lab needs and nothing more.
Mark Edwards
Oct 34 min read


ASTM D3787 Ball Burst Testing: A Complete Guide to the UniversalGripCo Ball Burst Puncture Fixture
Introduction In the field of textile and flexible material testing, understanding how a material behaves under multidirectional stress is critical for predicting real-world performance. Fabrics used in apparel, medical textiles, industrial materials, and geotextiles are frequently subjected to forces that do not occur purely along a single axis. Instead, these materials often experience localized pressure and multi-directional stress , which can lead to puncture or bursting f
Mark Edwards
Mar 267 min read


UniversalGripCo Arbor Press: Precision Force Application for Laboratory and Materials Testing
Arbor Press Cutting Sample Introduction In materials testing laboratories and engineering environments, many tasks require controlled compressive force to assemble components, prepare test fixtures, or install precision mechanical parts. While large automated systems such as universal testing machines handle tensile and compression testing, technicians frequently rely on smaller manual tools to prepare equipment and samples before testing begins. One of the most reliable too
Mark Edwards
Mar 266 min read


Environmental Chambers for Universal Testing Machines
Modern environmental chambers are designed to operate with any universal testing machine, regardless of manufacturer.
christopherthomasb
Feb 274 min read


ASTM C1161: Standard Test Method for Flexural Strength of Advanced Ceramics at Ambient Temperature
Introduction to ASTM C1161 Advanced ceramics are widely used in applications where high stiffness, thermal stability, wear resistance, and chemical inertness are required. Unlike metals or polymers, however, ceramics exhibit little to no plastic deformation and fail in a brittle manner. Because of this behavior, traditional tensile testing is often impractical or unreliable for ceramic materials. Instead, flexural strength testing has become the primary method for characteriz
Mark Edwards
Jan 307 min read


ASTM D1781 Climbing Drum Peel Test Fixture
This article provides a comprehensive technical overview of ASTM D1781, including the principles of the climbing drum peel test, required equipment, specimen preparation, grips and fixtures, data analysis, and best practices for achieving reliable and repeatable peel adhesion results.
Mark Edwards
Jan 238 min read


ASTM D5458 Peel Cling Test for Stretch Wrap Film: Setup, Fixture and Procedure
ASTM D5458 measures how strongly layers of stretch wrap film cling to each other, using a 20° inclined plane and a low-force tensile tester.
Mark Edwards
Jan 234 min read
bottom of page
